7. Measure flight mode current (condition:
Display & BL off/RF off/BT off)
Wait about 15 sec, back light will be off and
after 30 sec display will be off as well, in this
condition, please check current value on the
current meter.
Current value must be under
over, it means M/B failed, please replace M/B
for repair.
8. Measure power off current
Check current value on the current meter,
Current value must be under
it means M/B failed, please replace M/B for
repair.
If above measurement results are Pass both in
flight mode and power off mode, then the Main
board is judged as normal (Good)
If any of measurement modes is FAILED,
please replace the main board.
DOC- 00026415
REV.
2007/02/12
A01
N/A
43 of
70
TBD mA,