WOLF BUILT-IN OVENS
Planning Information
The M series oven can be installed in a standard or flush
inset application. If a cooktop is being installed above an
1
oven, a minimum of
/
"
is required between units. Loca-
(6)
4
tion of the electrical supply within the oven opening may
require additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
Single Oven
Double Oven
TRIM OVERLAP
Top
Bottom
Sides
DUAL INSTALLATION
Two 30" single M series ovens can be installed side by side
in a standard or flush inset application. A dual installation kit
is required. To maintain appropriate airflow, the ovens must
be installed into one opening. Any cosmetic or structural
material placed between the ovens will impede airflow and
is not recommended. Refer to illustrations on the following
pages.
The dual installation kit is available through an authorized
Wolf dealer. For local dealer information, visit the find a
showroom section of our website, wolfappliance.com.
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the oven can be placed in an adjacent cabinet
within reach of the conduit.
Performance may be compromised if the electrical supply is
less than 240 volts.
1
/
"
reveal is
(3)
8
The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground conductor.
The wiring diagram covering the control circuit is provided
with the oven.
MIN
ELECTRICAL REQUIREMENTS
250 lb
(115 kg)
SINGLE OVEN
400 lb
(181 kg)
Electrical Supply
Service
1"
(25)
Conduit
0"
(0)
Total Amps
11
/
"
(18)
16
Max Connected Load
Min Supply Wire
DOUBLE OVEN
Electrical Supply
Service
Conduit
Total Amps
Max Connected Load
Min Supply Wire
grounded, 240/208 VAC, 60 Hz
30 amp dedicated circuit
4'
(1.2 m)
22
5.4 kW
L1, L2, ground—10 AWG
grounded, 240/208 VAC, 60 Hz
50 amp dedicated circuit
5'
(1.5 m)
45
10.8 kW
L1, L2, ground—8 AWG
|