Dimplex WPM 2006 plus Operating Instructions Manual page 25

Heat pump controller
Table of Contents

Advertisement

Available languages

Available languages

System-specific parameters
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is raised. Operations to raise the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
Settings for heating circuit 2/3
Parallel shift of the set heating curve for heating circuit 2/3. By
pressing the arrow buttons once, the heating curve is shifted by
1°C upwards (warmer) or downwards (colder).
Settings to lower the heating characteristic curve of heating circuit
2/3
Sets the time during which the temperature in heating circuit 2/3 is
to be lowered.
Sets the temperature value by which the heating characteristic
curve of heating circuit 2/3 is to be lowered when the temperature
is lowered
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is lowered. Operations to lower the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
All settings to raise the heating characteristic curve of heating
circuit 2/3
Sets the time during which the temperature in heating circuit 2/3 is
to be raised.
Sets the temperature value by which the heating characteristic
curve of heating circuit 2/3 is to be raised when the temperature is
raised.
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is raised. Operations to raise the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
Settings for cooling operation
Sets the desired return set temperature when dynamic cooling is
selected
Sets the room set temperature for silent cooling
The actual value is measured by room climate control station 1
Sets the DHW preparation
Sets the desired hot water temperature
Sets the time programs for hot water blocks
Sets the times in which DHW preparation is blocked
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is lowered. Operations to lower the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
8.1
Setting range
N
T1
T2
Y
Indicator bar
00:00
...
23:59
0 K
...
19 K
N
T1
T2
Y
00:00
...
23:59
0 K
...
19 K
N
T1
T2
Y
10 °C
... 15 °C ...
30 °C
15.0 °C
... 20.0 °C ...
30.0 °C
30 °C
... 45 °C ...
85 °C
00:00
...
23:59
N
T1
T2
Y
E-8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wpm 2006 rWpm 2007 plusWpm 2007 r

Table of Contents