GAS SUPPLY
Installation must conform with all applicable gas codes.
3
A gas supply line of
/
"
rigid pipe must be provided
(19)
4
to the gas multifunction cooktop. If local codes permit, a
certified, 3'
long,
1
/
"
(.9 m)
(13)
2
appliance connector is recommended to connect the units
1
/
" NPT male inlet to the gas supply line.
2
When multiple gas cooktops or modules are installed side
by side, they can receive their gas supply from a common
line. However, each unit must have its own regulator
installed between the mainline and the cooktop or module.
Wolf natural gas cooktops will function up to 10,250'
in altitude without adjustment and LP gas cooktops
(3124 m)
will function up to 8,600'
(2621 m)
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
|
22
Wolf Customer Care 800.222.7820
or
3
/
"
ID flexible metal
(19)
4
. If the installation exceeds
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
LP GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
WC
5"
(12.5 mb)
7"
(17.5 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
WC
10"
(25 mb)
11"
(27.4 mb)
14"
, .5 psi
(34.9 mb)