Green VOR-IC6000-G Owner's Manual

Light commercial indoor cycle

Advertisement

Quick Links

Owner's Manual
VOR-IC6000-G
Light Commercial Indoor Cycle
Install Date: _________________________ Serial Number: ________________________
www.GreenSeriesFitness.com
© June 2015
Call Toll free at (800) 269-7130
VOR-IC6000-G
Revision 1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VOR-IC6000-G and is the answer not in the manual?

Questions and answers

Summary of Contents for Green VOR-IC6000-G

  • Page 1 Owner's Manual VOR-IC6000-G Light Commercial Indoor Cycle Install Date: _________________________ Serial Number: ________________________ www.GreenSeriesFitness.com © June 2015 Call Toll free at (800) 269-7130 VOR-IC6000-G Revision 1.1...
  • Page 2: Table Of Contents

    Important information, how often you exercise, how hard you exercise, how long you exercise, target heart rate zone. TECHNICAL SPECIFICATIONS ……………………………………………………….. 4 ASSEMBLY ……………………………………………………………………………...5-8 EXPLODED DRAWING………. ………………………………………………………… 9 PARTS LIST ………………………………………………………………………………10 INSTRUCTIONS FOR USE……………………………………………………………...11 WARRANTY …………………………………………………………………………..12-15 www.GreenSeriesFitness.com ©June 2015 Call Toll free at 800-269-7130 VOR-IC6000-G Revision 1.1...
  • Page 3: Important Safety Instructions

    Caution: If you experience chest pains, nausea, dizziness or shortness of breath, stop exercising Immediately and consult your physician before continuing. www.GreenSeriesFitness.com ©June 2015 Call Toll free at 800-269-7130 VOR-IC6000-G Revision 1.1...
  • Page 4: Safety Precautions

    =Maximum heart rate X 0.75 (This is recommended by American Heart Association. Before starting exercise program, please consult your physician to understand your physical situation) 220-your age = maximum heart zone www.GreenSeriesFitness.com ©June 2015 Call Toll free at 800-269-7130 VOR-IC6000-G Revision 1.1...
  • Page 5: Technical Specifications

    TECHNICAL SPECIFICATIONS VOR-IC6000-G Length: 43” (109 cm) Width: 24” (61cm) Height: 47” (119cm) Weight of product: 127 lbs. (55 kg) www.GreenSeriesFitness.com ©June 2015 Call Toll free at 800-269-7130 VOR-IC6000-G Revision 1.1...
  • Page 6 UNPACKING & ASSEMBLY VOR-IC6000-G www.GreenSeriesFitness.com ©June 2015 Call Toll free at 800-269-7130 VOR-IC6000-G Revision 1.1...
  • Page 7: Assembly

    ASSEMBLY VOR-IC6000-G Step 1: Front Foot Attach the front foot tube (#6) with the frame using (2) bolts (#3), (2) washers (#4) and (2) nuts (#5) as illustrated in the diagram and then tighten the bolts. Step 2: Rear Foot Attach the rear foot tube (#2) with frame then assemble (2) bolts (#3), (2) washers (#4) and (2) nuts (#5) as illustrated in the diagram and then tighten the bolts.
  • Page 8 (#26). 3. Adjust the handlebar (#11) position to your required position then tighten lock lever (#18) to secure. NOTE: Do not arise above safety line www.GreenSeriesFitness.com ©June 2015 Call Toll free at 800-269-7130 VOR-IC6000-G Revision 1.1...
  • Page 9 Step 6: Bottle Cage Attach a Bottle Cage (#9) to each side of the front forks and secure using the (2) Bottle Cage Fixed Screws (#10) for each Bottle Cage. www.GreenSeriesFitness.com ©June 2015 Call Toll free at 800-269-7130 VOR-IC6000-G Revision 1.1...
  • Page 10: Exploded Diagram

    Exploded Diagram VOR-IC6000-G www.GreenSeriesFitness.com ©June 2015 Call Toll free at 800-269-7130 VOR-IC6000-G Revision 1.1...
  • Page 11: Parts List

    Parts List VOR-IC6000-G part no. description q'ty part no. description q'ty 1 Main Frame 47 Screw M5*P0.8*6L 2 Rear Ground Tube 48 Sleeve8mm*15L 3 Groung Tube Fixed Bolt 49 Screw M5*P0.8*15L 4 Washer 50 Screw M8*P1.25*8L 5 Nut 51 Left Inner Cover...
  • Page 12: Instructions For Use

    INSTRUCTIONS FOR USE VOR-IC6000-G 1) The VOR-IC6000-G is designed to be used as an "indoor cycling" cycle in fitness studios and health clubs. It has a fixed wheel driven flywheel and should only be used under professional supervision. 2) Installation - It is important that the VOR-IC6000-G is correctly assembled and we recommend that installation and assembly be carried out by suitably qualified personnel.
  • Page 13 (10) years frame, five (5) years motor, three (3) years parts, two (2) years wearables and one (1) year labor from the initial install date. During this period, GREEN SERIES™ will repair or replace defective parts or equipment with new or reconditioned parts at GREEN SERIES™ option, without charge to customer.
  • Page 14: Warranty

    3. GREEN SERIES™ shall not be held liable or responsible for any damages to the units caused during the install of any product.
  • Page 15: Www.greenseriesfitness.com

    13. GREEN SERIES™ makes no warranty either expressed or implied regarding third-party (non-GREEN SERIES™) installed parts, accessories or modifications. 14. All GREEN SERIES™ equipment shall be properly cleaned and cared for in accordance to the procedures outlined the in the owner’s manual.
  • Page 16 (dependent on parts availability) via UPS. 3. GREEN SERIES™ will pay for shipping to and from the customer only within the time allocated under the warranty time-line following the original product installation date. Following this period all shipping fees for post warranty repairs are the sole responsibility of the customer.

Table of Contents