Berko FRA series Installation & Maintenance Instructions page 4

Fan forced wall heaters

Advertisement

Operation
1. Rotate the thermostat fully clockwise. This should
energize the heating elements and cause warm air to
flow from the hot air discharge at the openings in the bot-
tom of the grille.
NOTE: This heater is provided with a fan delay control that
allows the heating element to warm prior to the fan coming
on. This delay will also allow the fan to operate for a short
period after the heating element has been turned off to
remove the residual heat from the heater.
2. After the operation check, rotate the thermostat to
the desired position to obtain room comfort.
3. For continuous fan only operation (elements will not be
energized) rotate thermostat knob where indicator dot on
knob is aligned with "FAN".
NOTE: For best results, the heater should be left "ON"
constantly during the heating season because the thermo-
stat, when properly set, will maintain the desired tempera-
ture.
FRA4020B
MODEL NO.
FAN FORCED WALL HEATER
APPAREIL DE CHAUFFAGE MURAL À AIR PLUSÉ
VOLTS AC
60HZ
WATTS
HI LO
208
4000
MUST BE USED WITH AWH-BB BACK BOX
DO NOT OPERATE WITHOUT FRONT COVER IN PLACE.
DOIT ÉTRE UTILISÉ AVEC BOÎTIER ARRIÈRE AWH-BB
NE PAS UTILISER SI LE COUVERCLE AVANT N'EST PAS EN PLACE.
MARLEY ENGINEERED PRODUCTS
BENNETTSVILLE, SC 29512
Important Information
Maintenance
TO RESET MANUAL RESET LIMIT
Your heater is equipped with a manual reset safety thermal
limit control that will automatically turn the heater off to pre-
vent a fire if the heater overheats. This control is located on
the fan panel assembly between the element and fan blade
and marked "reset". The red reset button can be seen
through the front grille when the heater is installed. To reset,
allow the heater to cool, then push the red button that is vis-
ible through the hole in the fan panel. The heater should
immediately return to normal operation.
CAUTION
OPERATION OF THE MANUAL RESET SAFETY THERMAL LIMIT
CONTROL IS AN INDICATION THAT THE HEATER HAS BEEN
SUBJECTED TO SOME ABNORMAL CONDITION. IT IS RECOM-
MENDED THAT THE HEATER BE CHECKED BY A REPUTABLE
ELECTRICIAN OR REPAIR SERVICE TO ENSURE THE HEATER
HAS NOT BEEN DAMAGED.
Once each year the heater should be cleaned to remove dust
and other foreign material which has collected during the
heating season. This is a simple operation when performed
as follows:
CAUTION
DO NOT USE WATER OR DAMP CLOTH FOR CLEANING AND
DO NOT DISTURB THE HEATING ELEMENT.
1. Turn off the electric power at main line switch (or remove
all fuses) to disconnect electric power from the heater.
THIS IS IMPORTANT.
0106
DATE CODE:
PHASE
1
774G LISTED
ROOM HEATER
!
!
2. Remove thermostat knob.
3. Remove front cover by depressing plastic snap tabs with
a flat bladed screw driver as shown in Figure 5. Release
both tabs on one side then rotate the front cover off of the
fan deck.
Fig. 5
4. With a vacuum cleaner nozzle or dust cloth, remove dust
and other foreign material.
5. After cleaning, turn disconnect switch to ON position and
reinstall the grille.
6. Turn on the main line switch (or replace fuses) to restore
power to the heater. The heater is now ready for another
season of operation.