Sensor Temperature Monitoring Function - Toshiba HWS-803H-E Quick Reference

Hide thumbs Also See for HWS-803H-E:
Table of Contents

Advertisement

Sensor Temperature Monitoring Function

The sensor sensing temperature is displayed on the remote controller. This function allows you to make sure whether
the sensor is installed properly.
1) Press
+
buttons for four seconds or more.
2) Select the Code No. with the TEMP.
Code No.
Location
00
01
02
03
04
06
Hydro unit
07
08
09
0A
0B
0E
60
61
62
63
65
6A
Outdoor unit
6D
70
72
73
74
F0
F1
F2
Service Data
F3
F4
F5
F6
F7
3) Press
button to exit the test mode.
buttons.
Indication
Control Temperature (Hot water cylinder)
Control Temperature (Zone1)
Control Temperature (Zone2)
Remote controller sensor temperature
Condensed temperature (TC)
Water inlet temperature (TWI)
Water outlet temperature (TWO)
Water heater outlet temperature (THO)
Floor inlet temperature (TFI)
Hot water cylinder temperature sensor (TTW)
Motorized mixing valve position
Lo pressure (Ps) x 100
Heat exchanger temperature (TE)
Outside air temperature (TO)
Refrigerant discharge temperature (TD)
Refrigerant suction temperature (TS)
Heat sink temperature (THS)
Current value (in the inverter)
Heat exchanger coil temperature (TL)
Compressor operating frequency
Number of revolutions of outdoor fan (lower)
Number of revolutions of outdoor fan (upper)
Outdoor PMV position x1/10
Micro computer energized accumulation time
Hot water compressor ON accumulation time
Cooling compressor ON accumulation time
Heating compressor ON accumulation time
Hydro unit AC pump operation accumulation time
Hot water cylinder heater operation accumulation time
Hydro unit heater operation accumulation time
Booster heater operation accumulation time
32
Unit
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
step
MPa
°C
°C
°C
°C
°C
A
°C
Hz
rpm
rpm
pls
x100hrs
x100hrs
x100hrs
x100hrs
x100hrs
x100hrs
x100hrs
x100hrs

Hide quick links:

Advertisement

Table of Contents
loading