Burners
Auxiliary
Semi-rapid
Rapid
Wok
Test the operation of the cooker before leaving
Note: These burners have no aeration adjustment.
Check correct operation of the ignitions system and operation of the regulator and operation of the burners individually and in
combination. Burner flames should be clear blue, with no yellow tipping. If the burners show any abnormality check that the
burners are correctly located. If satisfactory performance cannot be obtained, contact Omega service.
Important
Before leaving instruct the owner in the use of the cooker it should be expressly noted that we cannot accept any liability for
direct or indirect damage caused by wrong connection or improper installation. When being repaired, the appliance must
always be disconnected from the mains supply; if required, notify our customer service.
 
TABLE N°1: Energy Consumption
Energy consumption
Gas type
Pressure (kPa)
1.0
Natural
2.75
U-LPG
1.0
Natural
2.75
U-LPG
1.0
Natural
2.75
U-LPG
1.0
Natural
2.75
U-LPG
TABLE N°2: GAS BURNER DIMENSION
Burner
Auxiliary
Semi-rapid
Rapid
Wok
7
Injector (mm)
Mj/hr
0.90
0.54
1.18
0.70
1.55
12
0.92
12
1.8
16
1.02
14.8
Dimension (mm)
Ø 50
Ø 70
Ø 95
Ø 125
Watts
4
4
7
7
3500W