Download Print this page

Murphy VS2 Series Specification Sheet page 2

Shock and vibration switch
Hide thumbs Also See for VS2 Series:

Advertisement

VS2 and VS2C
The VS2 and VS2C are designed for use in non-hazardous loca-
tions. They have leaf type SPDT, double make contacts that can
be used for shutdown and/or alarm. They have a slotted sensitivity
adjustment located on the side of the case (see drawing below).
SIDE VIEW
4-11/16 in.
(119 mm)
5-3/8 in.
(137 mm)
VS2C Model
2-1/4 in.
(57 mm)
VS2EX
• NEMA 7/IP50 Specifications
• Snap-switch Contacts
• TATTLETALE
®
Model VS2EX is housed in an explosion-proof enclosure with
threaded cover. This enclosure is CSA and UL listed for Class I,
Division 1, Groups C & D hazardous locations. In place of the
leaf type contacts, 2-SPDT snap-switches are used in this model.
Sensitivity is externally adjustable and, when tripped, the VS2EX
gives a TATTLTALE
®
indication on the reset button. It is con-
structed to meet NEMA 7 specifications.
ELECTRICAL
2-SPDT Switches (DPDT)
Contact Rating:
5 A @ 125–480 VAC
1/2 A @ 125 VDC
1/4 A @ 250 VDC
N.O.
2 A Resistive 30 VDC
1 A Inductive 30 VDC
N.O.
3-1/8 in.
Permanent
(80 mm)
Magnet
Reset
Push
Button
Mounting
Bracket
C-clamp
Mounting
Bracket
VS2C Model
Reset Button
COM
N.C.
COM
N.C.
NO1
FRONT VIEW
(Cover removed)
Air Gap
4-11/16 in.
(119 mm)
NO1
NC
COM
NO2
5-1/8 in. (130 mm)
Mounting Holes
4-40 NC
Screw
Terminal
Permanent
Magnet
TATTLETALE
®
Reset Push
Button
Air Gap
3/8 in.
(10 mm)
4 places
1/2 NPT
Conduit
4-7/8 in.
(124 mm)
1-3/4 in.
(44 mm)
VS-96013B page 2 of 4
ELECTRICAL
Contact Rating:
5 A @ 480 VAC
NC
COM
NO2
Adjustment
Armature
Slotted Sensitivity
Adjustment
1/2 Conduit
Threads
Weatherproof
Strain Relief
Bushing (VS2C)
1/4 x 1/2 in.
(6 mm x 13 mm)
Slot 2 places
5-5/8 in. (143 mm)
3 in.
(76 mm)
Mounting
Holes
5-1/4 in.
(133 mm)
NC
NO COM
Mounting
Holes
NC
NO COM
TOP VIEW
(Cover removed)
SENSITIVE
SIDE VIEW
6-3/8 in.
(162 mm)
Slotted
Sensitivity
Adjustment
MORE
LESS
SENSITIVE

Advertisement

loading

Related Products for Murphy VS2 Series

This manual is also suitable for:

Vs2cVs2exVs2exrVs2exrb