White Balance Adjustment - LG 39LY340H Service Manual

Hide thumbs Also See for 39LY340H:
Table of Contents

Advertisement

4.2. EDID Download
4.2.1. Overview
▪ It is a VESA regulation. A PC or a MNT will display an
optimal resolution through information sharing without any
necessity of user input. It is a realization of "Plug and Play".
4.2.2. Equipment
(1) Since EDID data is embedded, EDID download JIG, HDMI
cable is not need.
(2) Adjust by using remote controller
4.2.3. Download method
(1) Press Adj. key on the Adj. R/C.
(2) Select EDID D/L menu.
(3) By pressing Enter key, EDID download will begin
(4) If Download is successful, OK is display, but If Download is
failure, NG is displayed.
(5) If Download is failure, Re-try downloads.
※Caution : When EDID Download, must remove HDMI
Cable.
4.2.3.1. Models for EDID Data
not Deep Color, DTS + AC3 + PCM
DTS
2D
Ver 0.10
(1)8Bit_
(2)8Bit_
HD
FHD
RGB
88
-
HDMI1
6F8D
E78D
HDMI2
6F7D
E77D
not Deep Color, DTS + AC3 + PCM
PCM
Ver 0.10
(7_a)8Bit_
(7_b)8Bit_
HD
HD
RGB
88
-
HDMI1
6F08
6F08
HDMI2
6FF8
-
4.3. Tool Option Input
- Input Model Tool Option according to BOM
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
3D
(3)10Bit_
(4)8Bit_
(5)8Bit_
(6)10Bit_
FHD
HD
FHD
-
-
-
E746
6F60
E760
E736
6F50
E750
2D
(8_a)8Bit_
(8_b)8Bit_
(9)10Bit_
FHD
FHD
-
-
E708
E708
E7F8
-
5. Final Assembly Adjustment

5.1. White Balance Adjustment

5.1.1. Overview
5.1.1.1. W/B adj. Objective & How-it-works
(1) Objective: To reduce each Panel's W/B deviation
(2) How-it-works: When R/G/B gain in the OSD is at 192, it
means the panel is at its Full Dynamic Range. In order to
prevent saturation of Full Dynamic range and data, one of
R/G/B is fixed at 192, and the other two is lowered to find
the desired value.
(3) Adj. condition: normal temperature
- Surrounding Temperature: 25±5 ºC
- Warm-up time: About 5 Min
- Surrounding Humidity: 20% ~ 80%
- Before White balance adjustment, Keep power on status,
don't power off
5.1.1.2. Adj. condition and cautionary items
(1) Lighting condition in surrounding area surrounding lighting
should be lower 10 lux. Try to isolate adj. area into dark
surrounding.
(2) Probe location: Color Analyzer (CA-210) probe should be
within 10cm and perpendicular of the module surface
(80°~ 100°)
(3) Aging time
- After Aging Start, Keep the Power ON status during 5
FHD
Minutes.
-
- In case of LCD, Back-light on should be checked using no
signal or Full-white pattern.
E719
E709
5.1.2. Equipment
(1) Color Analyzer: CA-210 (NCG: CH 9 / WCG: CH12 / LED:
CH14)
(2) Adj. Computer(During auto adj., RS-232C protocol is
needed)
FHD
(3) Adjust Remocon
(4) Video Signal Generator MSPG-925F 720p/204-Gray
-
(Model:217, Pattern:49)
E7C1
→ Only when internal pattern is not available
E7B1
※ Color Analyzer Matrix should be calibrated using
CS-1000
- 10 -
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

39ly340c