Temperature And Humidity; Thermocouple Location; Figure 2-2 Drive Base Casting Thermocouple Location - Western Digital WD15NPVX Technical Reference Manual

Wd green mb500m-6gb sata 6 gb/s hard drives
Hide thumbs Also See for WD15NPVX:
Table of Contents

Advertisement

WD Green MB500M-6Gb
Rotational Shock Non-Operating
Drives are tested by applying a rotational force centered around the actuator pivot. The drive incurs no
physical damage when subjected to the rotational force specified in Table 2-1.
Packaged Shock and Vibration
The shipping packaging is designed to meet the National/International Safe Transit Association
(N/ISTA) standards for packaged products. The drive incurs no physical damage when subjected to the
N/ISTA standards.
2.5.2
Temperature & Humidity
Operating ambient temperature
Max base casting temperature
Humidity
Thermal Gradient
Humidity Gradient
Non-operating Temperature
Humidity
Thermal Gradient
Humidity Gradient
1
The system environment must allow sufficient air flow to limit maximum surface temperatures as defined.
2
See Figure 2-2.
2.5.3
Figure 2-2. Drive Base Casting Thermocouple Location
2679-771422-A00

Temperature and Humidity

1
0°C to 60°C (32°F to 140°F)
2
60°C (140°F)
8-90% RH non-condensing
29.4°C (maximum wet bulb)
20°C/hour (maximum)
20%/hour (maximum)
-40°C to 65°C (-40°F to 149°F)
5-95% RH non-condensing
40°C (maximum wet bulb)
30°C/hour (maximum)
20%/hour (maximum)

Thermocouple Location

Component
Drive base casting
RELEASED 5/2/13 (WD CONFIDENTIAL)
Specifications
Location
#1, Figure 2-2
9