Heating Characteristic at Different Piping Length
Condition
Indoor room temperature: 20/-°C, 7/6°C
Remote control setting: HI FAN, HEAT 30°C
Compressor frequency: F
h
44.000
43.000
42.000
41.000
40.000
39.000
3
5
7
9
11
8.700
8.200
7.700
7.200
3
5
7
9
11
3.200
3.100
3.000
2.900
2.800
3
5
7
9
11
12.200
12.000
11.800
11.600
11.400
11.200
11.000
10.800
3
5
7
9
11
13
15
17
19
21
23
Piping Length (m)
13
15
17
19
21
23
25
Piping Length (m)
13
15
17
19
21
23
25
Piping Length (m)
13
15
17
19
21
23
Piping Length (m)
84
230
25
27
29
31
27
29
31
27
29
31
25
27
29
31