4. TRIAL-RUNNING

4.1 Water affusion before operation
Before using this unit, please follow the steps below.
Water Affusion: If the unit is used for the first time or used again after
emptying the tank, please make sure that the tank is full of water
before turning on the power.
Fig.4-1
Method: see
Open the cool water inlet valve and the hot
water outlet valve.
Open
Cool water inlet
When water flows out from the water
outlet, the tank is full. Turn off the hot water
outlet valve and water affusion is finished.
Hot water outlet
CAUTION
Operation without water in water tank may result in the
damage of auxiliary e-heater. Due to such damage,
manufacturer will not be liable for any damages caused by
this issue?
After powered on, the display lights up. Users can operate the
unit through the buttons under the display
Emptying: If the unit needs cleaning, moving etc, the tank
should be emptied.
Method: See Fig.4-2:
Close the cool water inlet valve, open the hot
water outlet valve and open drainpipe.
Close
Cool water inlet
Installation & Owner's Manual
10
Open
Hot water outlet
Water Affusion
Close
Water out
Fig.4-1
Open
Hot water outlet
Open
Drainpipe shut-off valve
After emptying, please replace the nut of
drainpipe.
Close
Drainpipe shut-off valve
4.2 Trial- running
4.2.1 Checking list before commisionning.
1)
Checking list before trial-running.
2)
Correct installation of the system.
Correct connection of water/air piping and wiring;.
3)
4)
Condensate draining smoothly well insulation work for all
hydraulic part.
5)
Correct power supply.
No air in the water pipeline and all valves opened.
6)
7)
Effective electric leakage protector installation.
8)
Sufficient inlet water pressure (between 0.15MPa and 0.65MPa).
4.2.2 About Running
System Structure Figure
1)
Unit has two kinds of heat sources: heat pump(compressor)
and electric heater.
Unit will automatically select heat sources to heat water to the
target temperature.
Water outlet
Temperature sensor(T5U)
Water inlet
Temperature sensor(T5L)
Electric heater
2)
Water Temperature Display
The temperature shown on the display depends on the upper
sensor. So it is normal that the display temperature has reached
to target temperature but compressor still running, because the
lower water temperature does not get to target temperature.