Installation Checklist - Sinclair SWH-15/190T Owner's Manual

Table of Contents

Advertisement

3.3.4 Switch setting
PCB has 2 bits of switches.
Model selection (User never allow to alter the factory settings)
Without Electric Heater
Without Disinfect
Model selection (User never allow to alter the factory settings)
190L model
Default factory setting is:
SW1
3.3.5 Electric leakage protector
Creepage Protector
GND

3.4 Installation checklist

3.4.1 Location
The flooring beneath the water heater must be able to support
the weight of the unit when filled with water (more than 286kg).
Located indoors (such as a basement or garage) and in a
vertical position. Sheltered from freezing temperatures.
Provisions made to shelter the area from water damage.
Metal drain pan installed and piped to an adequate drain.
Sufficient room to service the water heater.
Sufficient air for the heat pump to function,
the water heater must be located in a space >15m³, and must
have unrestricted air flow.
NOTE
For optimal efficiency and serviceability, the following clearances
should be maintained: 800mm on the air inlet side, 800mm on the
air outlet side, 600mm in the back, and 600mm in the front.
The unit cannot be placed into any type of closet or small
enclosure.
The site location must be free from any corrosive elements in
Table 3-4
With Electric Heater
With Disinfect
Table 3-5
300L model
SW2
Fig.3-13
Power Cable with
Creepage Breaker
Fig.3-14
the atmosphere such as sulfur, fluorine, and chlorine. These
elements are found in aerosol sprays, detergents, bleaches,
cleaning solvents, air fresheners, paint, and varnish
removers, refrigerants, and many other commercial and
household products. In addition excessive dust and lint may
affect the operation of the unit and require more frequent
cleaning.
The ambient air temperature must be above -7ºC and below
43ºC If the ambient air temperature falls outside these upper
and lower limits the electrical elements will be activated to
meet the hot water demand.
3.4.2
Water System Piping
PT valve(Temperature and pressure relief valve) properly
installed with a discharge pipe run to an adequate drain and
sheltered from freezing.
All piping properly installed and free of leaks.
Unit completely filled with water.
Water temperature limit valve or mixer tap(recommanded)
installed per manufacturer's instructions.
3.4.3
Condensate Drain Line Installation
Must be located with access to an adequate drain or
condensate pump.
Condensate drain lines installed and piped to an adequate
drain or condensate pump.
3.4.4 Electrical Connections
The water heater requires 220 VAC for proper operation.
Wiring size and connections comply with all local applicable
codes and the requirements of this manual.
Water heater and electrical supply are properly grounded.
Proper overload fuse or circuit breaker protection installed.
3.4.5 Post Installation Review
Understand how to use the User Interface Module to set the
various modes and functions.
Understand the importance of routine
inspection/maintenance of the condensate drain pan and
lines. This is to help prevent any possible drain line
blockage resulting in the condensate drain pan overflowing.
IMPORTANT: Water coming from the plastic shroud is an
indicator that both condensation drain lines may be blocked.
Immediate action is required.
To maintain optimal operation check, remove and clean the
air filter.