Configuration and Programming by the Engineer
Tamper circuit "02=Tamper"
Tamper circuit "02=Tamper"
A tamper circuit is used for monitoring the enclosures of connected
components. Depending on the classification of the risk, it is necessary to
include the cover contact of the external sirens and the setting device in the
tampering circuit. A tampering alarm may only be reset by the Engineer.
Reaction to a circuit fault:
Unset:
A circuit fault triggers an internal alarm and is indicated on the keypad:
On the keypad by flashing of the LED and as a display (criteria) of the
faulty circuit after a setting attempt.
– The output "Internal alarm", the buzzer in the panel and in the
keypads are actuated.
After a reset:
The output "Internal alarm", the buzzer in the panel and in the
keypads are switched off.
The stored alarms are deleted.
The time/date and "Unset" are shown on the keypad in the display.
The LED lights up.
Internal set:
The output "Internal alarm", the buzzer in the panel and in the
keypads are actuated for 180 seconds.
The LED flashes on the keypad.
After unsetting:
The output "Internal alarm", the buzzer in the panel and in the
keypads are switched off.
On the keypad, the triggered circuit is shown for 4 seconds in the
display and then the reset request is displayed.
The LED flashes.
After a reset:
The stored alarms are deleted.
The time/date and "Unset" are shown on the keypad in the display.
The LED lights up.
External set:
The output "Intruder" and the sirens are actuated for 180 seconds.
The strobe and the permanent alarm relay are actuated.
After unsetting:
The sirens are switched off.
The buzzer in the panel and in the keypads are actuated.
The time/date and "Unset" are shown on the keypad in the display.
The LED flashes.
After a reset:
The stored alarms are deleted.
The strobe and the permanent alarm relay are switched off.
The time/date and "Unset" are shown on the keypad in the display.
The LED lights up.