5-5. Finishing the Installation

After finishing insulating and taping over the tubing, use sealing
putty to seal off the hole in the wall to prevent rain and draft
from entering. (Fig. 5-10)
Apply putty here
Confirm the "Checkpoint" under the section "8. PRECAUTIONS
ON TEST RUN" after installation of indoor and outdoor units,
panels and electrical wiring.

6. FINAL PROCEDURE

Reinstall the removed part to be placed in its original position.
(See the section "3-2. Preparation Before Installation".)
Then install the accessory supplied side covers (L/R) on both
sides of the indoor unit.
Attach the supplied side plates.
Insert the side plates in the direction of the arrow and fix
them with 2 screws once you've removed.
Attach the accessory supplied side covers.
Slide the covers from the front side and attach to the claws of
the latches.
Tighten the screws (accessory supplied).
Tubing
Fig. 5-10
Side plate
Screw
Attach
Side cover (accessory supplied)
Screw (accessory supplied)
Fig. 6-1
● Attach the air-intake grille.
When attaching the air-intake grille, perform the reverse
procedure to removing the grille.
Refer to the section "3-2. Preparation Before Installation".
Be sure to attach the safety string.
Close the air-intake grille and fix the claws of the latches with
the screws.
7. HOW TO INSTALL TIMER REMOTE
CONTROLLER OR HIGH-SPEC WIRED
REMOTE CONTROLLER (OPTIONAL
PART)

NOTE

Refer to the Operating Instructions attached to the optional
Timer Remote Controller or optional High-spec Wired Remote
Controller.