DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- To open the appliance first remove the filter cover (item 31)
and then remove the 5 screws from the appliance.
- To remove the hinge,
first remove the end caps
(item 16) this can be done
with a screwdriver,
see picture.
- When the end caps are
removed, the hinging pin
can be removed.
- When this is done the hinge can be taken off the appliance.
- Remove the can with the filters.
- To remove the housing (7 screws) you will require for some
screws a screwdriver with a 14.5 cm long shrank for this.
Screwdriver 4322 009 08490 for T15 can be used.
- When the repair is finished, check whether all functions of
the appliance work properly.
- To disassemble the cord winder, use TORX screwdriver no.
T10, which is one of a set consisting of T20; T15; T10; T9;
T8; T7 and T6 (code number 4822 395 505145)

ELECTRICAL DIAGRAM

MOTOR
POWER
MODULE
Brown
Black
Black
M
Blue
CORD WINDER
Blue
Brown
Black
Further disassembly advise for the hinge:
- The chromium ornamental
plate can be removed with
a screwdriver (see picture)
after that the min/max
button and the On/Off
button can be removed
from the plate.
- Remove the screw (B) underneath the ring with a T15
screwdriver; the orange user panel (item 4) can be removed.
- Choke assy can be taken out.
- PCB can be removed.
- To remove the sealing disk and the detector with the spring
you have to remove the 2 screws (C) next to the sealing
disk.

REPAIR INSTRUCTION

- If the reel half spring unit is replaced, shaft
lubricated with silicone grease. Do not apply any silicone
grease to or spill any grease on terminals (item 46) or
conductors (item 47).
- The cord winder spring must be tensioned to the maximum
level and the be rewound approx 1.5 turn.
- Item 5, air valve, opens to cool the motor if the air
displacement is too low or if the airflow is blocked.
- If the function of the electronic control unit is not required,
the Triac must be short-circuited in the manner shown in
the circuit diagram.
Triac