Refrigerant System Diagram - Mitsubishi MSZ-GE22VA Service Manual

Indoor unit
Hide thumbs Also See for MSZ-GE22VA:
Table of Contents

Advertisement

7

REFRIGERANT SYSTEM DIAGRAM

MSZ-GE22VA MSZ-GE25VA MSZ-GE35VA MSZ-GE42VA MSZ-GE50VA
MSZ-GE60VA MSZ-GE71VA
Indoor coil
Indoor
thermistor
heat
RT12 (main)
exchanger
Indoor coil
thermistor
RT13 (sub)
Room temperature
thermistor
RT11
Indoor coil
Indoor
thermistor
heat
RT12 (main)
exchanger
Indoor coil
thermistor
RT13 (sub)
Room temperature
thermistor
RT11
10
Refrigerant pipe ø9.52 (MSZ-GE22/25/35/42VA)
ø12.7 (MSZ-GE50VA)
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35
(with heat insulator)
Refrigerant flow in cooling
Refrigerant flow in heating
Refrigerant pipe ø15.88
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35 (MSZ-GE60VA)
ø9.52 (MSZ-GE71VA)
(with heat insulator)
Refrigerant flow in cooling
Refrigerant flow in heating
Unit: mm

Hide quick links:

Advertisement

Table of Contents
loading