Siemens Gigaset 4010 Micro Service Manual page 5

Table of Contents

Advertisement

Feature
Pause after signal-key
Automatic attenuation correction
(dependant on country)
Time for end of call identification
(to distinguish between 2 ringing pulses of
one call with long pauses between pulses
and 2 separate calls)
Hook-flash-prevention (cradle switch
identification) (short press on cradle switch-
key is extended by SW to prevent that it is
interpreted as a press on the flash-key)
Pause after line seizure
System PIN reset
Programming data on an address
Read out SW-version
Range of ringing frequency recognition
Dial pulsing: pulse pause ratio
CLIP activation
Off-hook CLIP activation
Approval test
Gigaset 4015 Micro (country specific (e.g. Switzerland)):
Feature
Select speech 1 for AM phrases (tones)
Select speech 2 for AM phrases
Select speech 3 for AM phrases
Select speech 4 for AM phrases
X 76200 Y
1
-
2 1 = 800 ms
2 = 1600 ms
3 = 3200 ms
1
-
3 0 = off
1 = on
1
-
4 0 =
1 = 5.5 sec.
2 =
3 = 11 sec.
1
-
5 0 = 800 ms
1 = 2000 ms
1
-
6 1 =
2 =
3 =
4 = 2.5 sec.
3 76200
-
4 76200 1 Specific code needed
4 76200 2 Example: 01002_.....
01 = SW-variant
002 = SW-version
4 76200 3 0 = 23- 54 Hz
1 = 20- 60 Hz
2 = 15-75 Hz
4 76200 4 0 = 1.5 : 1
1 = 2 : 1
4 76200 5 Select 0 (on) or 1 (off)
4 76200 6 Select 0 (on) or 1 (off)
6 76200 6
X 76200 Y
2
-
1
2
-
2
2
-
3
2
-
4
Option
4 sec.
7 sec.
1 sec.
3 sec.
7 sec.
-
-
Option
-
-
-
-

Advertisement