Sony TRINITRON KV-HR36M91 Service Manual page 7

Table of Contents

Advertisement

KV-HR36M61/HR36M91
RM-1007
RM-1007
3.
Blinking count display of
< FRONT PANEL >
L(MONO)
R
AUTO PROG
PROG
4
MENU
1 indicator
Release of
1 indicator blinking.
The STAND BY indicator blinking display is released by turning OFF the power switch
on the TV main unit or removing the plug from the power.
But in the RLY ERR (10 times blinking), do not release by tuning power off.
For details, refer to the item 1-6.
4.
Self-diagnosis screen displays
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when
the screen disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether
the detection circuit operated or not) in order to allow confirmation.
<Screen Display Method>
Quickly press the remote command button in the following order from the standby state.
b
Self-diagnosis screen display
1 indicator
* One blink is not used for self-diagnosis.
¥EXAMPLE
<Diagnosis Items> <Number of Blinks>
¥ +B overcurrent
¥ +B overvoltage
¥ Vertical deflection stop
Lamp ON : 0.3 seconds
Lamp OFF : 0.3 seconds
5
b
b
=/1
˘
Be aware that this differs from the method of
entering the service mode (
2 times
3 times
4 times
+ ).
• "G" : OK, "NG" : DETECTS ONCE OR MORE
• THE 10 DIGITS OF NUMERALS ARE FOR CHECKING,
NO RELATION TO DIAGNOSIS.
• 101 : NO LED BLINKING FOR WDT.
"0" : NUMBER OF DETECTION.
– 6 –
Lamp OFF :
3.0 seconds

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trinitron kv-hr36m61

Table of Contents