Advanced Recording Operations; Adjusting Bias And Recording Level Calibration Automatically - Sony TC-WA8ESA Operating Instructions Manual

Hide thumbs Also See for TC-WA8ESA:
Table of Contents

Advertisement

Advanced Recording Operations

Adjusting Bias and Recording
Level Calibration
Automatically
Since there are many different types of cassettes on the
market, your tape deck automatically sets the
appropriate equalization characteristics and bias
current for each tape type (ATS: Automatic Tape
Selection). However, you can get better recording
results by doing the automatic bias current and the
recording level calibration. You can do automatic
calibration on either deck (TC-WA8ESA/WE805S only)
or only on deck B (on all other models).
DECK A / DECK B
RESET
MEMORY
A
COUNTER
POWER
g
DIRECTION MODE
RMS
A
a
RELAY
RMS/START
SET
CHECK
DISPLAY
– RMS +
0
(AMS)
(AMS)
)
Ø
ON
ø
OFF
ª
·
p
PITCH CONTROL
CLEAR
BACK
FRONT
DOLBY NR
PAUSE
REC MUTE
REC
OFF
ON
ON FILTER
P
R
r
+
§
PAUSE P
ª / · PAUSE P
1
Insert the cassette you want to record on into
deck B or into either deck (TC-WA8ESA/WE805S
only).
Make sure the record-protect tabs on the cassette
have not been removed.
2
Press DECK A or DECK B on the TC-WA8ESA
and WE805S, or AUTO CAL on all other models
until "CAL" appears in the display.
3
Press · or ª to select the side of the tape to be
recorded.
To select
Press
The front side
·
The reverse side
ª
ª / ·
B
RESET
MEMORY
AUTO
REC LEVEL
5
4
6
3
7
2
8
1
9
AUTO CAL(STARTP)
DUBBING A
B
0
10
DECK A
DECK B
A+B REC
HIGH/NORMAL
START(DECK BP)
FADER
ARL
0
(AMS)
(AMS)
)
π SYNCHRO
ª
·
p
B
C
S
PAUSE
REC MUTE
REC
PHONES
P
R
r
§
Advanced Recording Operations
4
Press PAUSE P to start the automatic calibration
procedure.
The automatic calibration procedure starts (i.e.,
recording test tones, rewinding, and playing
back).
During the calibration, the counter changes from
9 to 0.
CAL B
When the automatic calibration procedure ends,
the tape rewinds to the original position, the
counter returns to normal and the tape deck
stops.
5
Start the actual recording (see page 6).
To cancel the automatic calibration function
Press p on the deck you're using.
If "A" or "B" on the TC-WA8ESA and WE805S or
"CAL" on all other models flashes continuously
The automatic calibration procedure has been interrupted
by:
— The end of the tape. Reverse the tape direction or rewind
the tape to a new position that allows recording of the
test tone.
— Damaged tape or dirty heads. Change the cassette or
clean and demagnetize the heads (see page 19).
Updating the calibration setting
If you insert a cassette and "[A] CAL" or "CAL [B]" on
the TC-WA8ESA and WE805S or "CAL" on all other
models appears in the display, it means that automatic
calibration data in that deck for that tape type (I, II or
IV) exists. However, we recommend that you repeat
the automatic calibraion procedure each time you
insert a new cassette since cassettes of the same type
also vary in their characteristics.
Before recalibrating, be sure to turn off "[A] CAL" or
"CAL [B]" on the TC-WA8ESA and WE805S or "CAL"
on all other models by pressing DECK A or DECK B on
the TC-WA8ESA and WE805S or AUTO CAL on all
other models. Then start from Step 2 of the automatic
calibration procedure.
CA. L9
REC
3-810-716-11(1)
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc-wa7esaTc-we805sTc-we705sTc-we605sTc-wr550zTc-we505

Table of Contents