Acer V193 Service Manual page 28

Acer computer monitor
Hide thumbs Also See for V193:
Table of Contents

Advertisement

3.4.1.2 AC-DC Output Specification
Tolerance
Output oltage
---
+5Vdc
+5 /-3 %
+19Vinv
+35/-5 %
±5%
+5Vaudio
Measured at DC output
terminals which are
Ripple
paralleled with a 10uf
Ecap &0.1uf Ceramic
cap.
Noise
2.Band width is limited
within 20MHz
50~100% or 100~50%
Dynamic Load
load change of any DC
Regulation
output @50% duty of
Over / Under
@ Power line on/off
Sh
*+5Vdc load regulation test: the +19Vinv loading at 2.0A
*+19Vinv load regulation test: the +5Vdc loading at 1.5A
3.4.1.3 Protection function
1) SCP: Short circuit protection must be acted on both outputs
2) OPP: Should be protected when output power consumption is within ~ 55W
Inverter Electrical Specification:
For 19" Panel
Input Voltage
Input Current
Backlight ON/OFF
Control
Brightness Adjust
Output Voltage
Brightness
Output Current(Each
connector)
Frequency
Lamp start voltage
Output Current
MIN
0.05A
0A
0A
---
---
---
---
Condition
---
---
ON
OFF
Min. Luminance / Max.
Luminance
Vin=19V, Iout=7mA
lamp current in 7mA
Vbri=0.4V~3.3V
---
@0℃
MAX
1.5A
2A
0.6A
1%
3%
±5%
±10%
Min.
Typ.
---
19
---
1.5
3.3
0
---
30%
---
650
250
300
4
7.5
40
---
1650
---
- 28 -
Voltage Tolerance
4.85~5.25V dc
24~18Vdc
4.75~5.25Vdc
+5Vdc:50mVp-p
+19Vinv:190mVp-p
+5Vdc:150mVp-p
+19Vinv:570mVp-p
---
---
Max.
Unit
---
V
---
A
V
V
---
---
---
Vrms
---
Cd/m²
8
mA
60
KHz
---
Vrms

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents