Power Source Requirements
External Fusing
Internal Fusing
Fluid Capacity
Control
DMX 512
Typical Smoke Output
Machine Dimensions
Weight (Fluid Not Included)
Only Le Maitre® Ltd Smoke Fluids should be used.
may cause incorrect operation and could cause toxicity issues.
Replacing fluid merely requires the changing the empty bottle for a new
one. Use the screw lid to seal the used bottle and dispose of correctly. Re
filling the empty bottle is not advised as this can lead to the introduction of
foreign particles which may reduce the efficiency of the external in-line
filter. If it is felt that there is a reduction in the performance of the machine
then this filter should be checked and cleaned. Never operate the machine
with this filter removed.
Any spillage should be cleaned away. The fluid does not require anything
other than a water based cleanser.
This machine should not be run without fluid for any length of
time as this will cause pump failure.
Fluid pump Priming should be performed at the maximum
smoke output, to ensure a quick and air lock free process.
Page 1
Please return this manual with your hire or a charge of £5 will be made
Lemaitre Gforce 3
Smoke Machine
230VAC 2200 Watt 50Hz
12AT ceramic
500mA PCB transformer
Detachable 5 Litres Bottle Carrier
Manual or DMX
3 channels Output, Smoke On delay, Aux Fan
3
1100 m
/min. 500 m
L41 W29 H20
12Kgms
Fluid Use
3
/min continuous
Use of other fluid
M93