Wiring Configuration: Basic Models (He100/He200) - Honeywell trueease Installation Manual

Hide thumbs Also See for trueease:
Table of Contents

Advertisement

Available languages

Available languages

Wiring Configuration: Advanced Models (HE150/HE250/HE300)
Wiring TrueEASE to equipment with powered terminals.
HE150 OR HE250
COM
HUM
1
ADD 24VAC ISOLATION RELAY (SUCH AS R8222B1067) BETWEEN
1
THE HUMIDIFIER AND THE AIR HANDLER.
THE 50027910-001 AIR-FLOW SWITCH (AFS) IS RECOMMENDED
2
TO ENSURE AIR FLOW WHEN THE HUMIDIFIER IS RUNNING. IF
THE AFS IS USED, SET DIP SWITCH 1 TO OFF (LEFT).
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
3
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
WIRING DIAGRAM ASSUMES THE USE OF EQUIPMENT-SPECIFIC
4
COMMUNICATING THERMOSTAT CONTROLLING THE HUMIDIFIER.

Wiring Configuration: Basic Models (HE100/HE200)

Wiring TrueEASE to equipment with powered terminals.
Humidifier 69-2413EF—05
4
R
G
AFS
2
3
POWER IN
DIP SWITCH SETTING
RESET POWER AFTER
ANY DIP SWITCH CHANGES
COM
HUM
R
G
1
WIRING DIAGRAM ASSUMES THE USE OF EQUIPMENT-SPECIFIC
COMMUNICATING THERMOSTAT CONTROLLING THE HUMIDIFIER.
HE300
COM
HUM
3
POWER IN
ADD 24VAC ISOLATION RELAY (SUCH AS R8222B1067) BETWEEN
1
THE HUMIDIFIER AND THE AIR HANDLER.
THE 50027910-001 AIR-FLOW SWITCH (AFS) IS RECOMMENDED
2
TO ENSURE AIR FLOW WHEN THE HUMIDIFIER IS RUNNING. IF
THE AFS IS USED, SET DIP SWITCH 1 TO OFF (LEFT).
HE300 USES A LINE CORD PLUG.
3
WIRING DIAGRAM ASSUMES THE USE OF EQUIPMENT-SPECIFIC
4
COMMUNICATING THERMOSTAT CONTROLLING THE HUMIDIFIER.
1
HUMIDIFIER
WATER
SOLENOID
LEAD WIRE
M33039
4
R
G
AFS
2
1
M33040