Lamp run blinking, lamp timer still on
1 comments:
Mr. Anderson
May 27, 2025
When the lamp is blinking on a Mitsubishi Heavy Industries SRK05CM unit while the TIMER light is still on, it indicates a trouble condition. Specifically:
- If the RUN light blinks once and the TIMER light is ON, it means a heat exchanger sensor error (e.g., sensor wire disconnection or temperature ≤ –28ºC for 15 seconds). - If the RUN light blinks twice and the TIMER light is ON, it indicates a room temperature sensor error (e.g., wire disconnection or temperature ≤ –45ºC for 15 seconds).
This signals the unit has stopped due to a detected fault.
This answer is automatically generated
Subscribe to Our Youtube Channel
Related Manuals for Mitsubishi Heavy Industries SRK05CM
'10 • SRK-T-099 '13•SRK-T-141 (7) Phenomenon observed after shortcircuit, wire breakage on sensor ..49 (8) How to make sure of wireless remote control ........50 ■How to read the model name Example: SRK 05 C Series code Cooling only type Product capacity Model name SRK : Wall mounted type...
'13•SRK-T-141 1. SPECIFICATIONS SRK05CM Model Item Indoor unit SRK05CM Outdoor unit SRC05CM Cooling capacity (1) 1500 Power supply 1 Phase, 220V, 50Hz Power Cooling 0.42 consumption Running Cooling current Operation data (1) Inrush current Cooling 3.57 Noise Cooling Sound level...
Page 6
'13•SRK-T-141 SRK05CM-3 Model Item Indoor unit SRK05CM-3 Outdoor unit SRC05CM-3 Cooling capacity (1) 1465 Power supply 1 Phase, 220 - 240V, 50Hz Power Cooling 0.375 consumption Running Cooling current Operation data (1) Inrush current Cooling 3.91 Noise Cooling Sound level...
Page 7
'13•SRK-T-141 SRK05CMP-3 Model Item Indoor unit SRK05CMP-3 Outdoor unit SRC05CMP-3 Cooling capacity (1) 1465 Power supply 1 Phase, 220 - 240V, 50Hz Power Cooling 0.49 consumption Running Cooling 2.3 / 2.2 current Operation data (1) Inrush current Cooling 2.99 Noise Cooling Sound level dB(A)
Page 8
'13•SRK-T-141 SRK09CM-3 Model Item Indoor unit SRK09CM-3 Outdoor unit SRC09CM-3 Cooling capacity (1) 2638 Power supply 1 Phase, 220 - 240V, 50Hz Power Cooling 0.90 consumption Running Cooling 4.2 / 4.0 current Operation data (1) Inrush current 21.0 Cooling 2.93 Noise Cooling Sound level...
Page 9
'13•SRK-T-141 SRK09CM-4 Model Item Indoor unit SRK09CM-4 Outdoor unit SRC09CM-4 Cooling capacity (1) 2638 Power supply 1 Phase, 220 - 240V, 50Hz Power Cooling 0.90 consumption Running Cooling 4.2 / 4.0 current Operation data (1) Inrush current 21.0 Cooling 2.93 Noise Cooling Sound level...
Page 10
'13•SRK-T-141 SRK09CM-5 Model Item Indoor unit SRK09CM-5 Outdoor unit SRC09CM-5 Cooling capacity (1) 2638 Power supply 1 Phase, 220 - 240V, 50Hz Power Cooling 0.90 consumption Running Cooling 4.2 / 4.0 current Operation data (1) Inrush current 21.0 Cooling 2.93 Noise Cooling Sound level...
Page 11
'13•SRK-T-141 SRK09CMP-3 Model Item Indoor unit SRK09CMP-3 Outdoor unit SRC09CMP-3 Cooling capacity (1) 2500 Power supply 1 Phase, 220 - 240V, 50Hz Power Cooling 0.925 consumption Running Cooling 4.7 / 4.6 current Operation data (1) Inrush current 21.0 Cooling 2.70 Noise Cooling Sound level...
Page 12
'13•SRK-T-141 SRK09CMP-4 Model Item Indoor unit SRK09CMP-4 Outdoor unit SRC09CMP-4 Cooling capacity (1) 2500 Power supply 1 Phase, 220 - 240V, 50Hz Power Cooling 0.925 consumption Running Cooling 4.7 / 4.6 current Operation data (1) Inrush current 21.0 Cooling 2.70 Noise Cooling Sound level...
Page 13
'13•SRK-T-141 SRK12CM-3 Model Item Indoor unit SRK12CM-3 Outdoor unit SRC12CM-3 Cooling capacity (1) 3517 Power supply 1 Phase, 220 - 240V, 50Hz Power Cooling 1.09 consumption Running Cooling current Operation data (1) Inrush current 25.0 Cooling 3.23 Noise Cooling Sound level dB(A) level Exterior dimensions (Height x Width x Depth)
Page 14
'13•SRK-T-141 SRK12CM-4 Model Item Indoor unit SRK12CM-4 Outdoor unit SRC12CM-4 Cooling capacity (1) 3517 Power supply 1 Phase, 220 - 240V, 50Hz Power Cooling 1.09 / 1.11 consumption Running Cooling 5.1 / 5.0 current Operation data (1) Inrush current 25.0 Cooling 3.23 / 3.17 Noise...
Page 15
'13•SRK-T-141 SRK12CM-5 Model Item Indoor unit SRK12CM-5 Outdoor unit SRC12CM-5 Cooling capacity (1) 3517 Power supply 1 Phase, 220 - 240V, 50Hz Power Cooling 1.09 consumption Running Cooling current Operation data (1) Inrush current 25.0 Cooling 3.23 Noise Cooling Sound level dB(A) level Exterior dimensions (Height x Width x Depth)
'13•SRK-T-141 5. RANGE OF USAGE & LIMITATIONS Models All model Item Indoor return air temperature ( Upper, lower limits ) Refer to the selection chart Outdoor air temperature ( Upper, lower limits ) Refrigerant line ( one way ) length Max.
Page 26
'13•SRK-T-141 (2) Correction of cooling capacity in relation to one way length of refrigerant piping Model SRK05CM Piping length [m] Cooling 0.99 0.975 Models SRK05CM-3 SRK05CMP-3 SRK09CM-3, 09CM-4, 09CM-5 SRK09CMP-3, 09CMP-4 SRK12CM-3, 12CM-4, 12CM-5 Piping length [m] Cooling 0.985 0.97...
'13•SRK-T-141 6. APPLICATION DATA Models SRK05CM, 05CM-3 SRK09CM-3, 09CM-4, 09CM-5 SRK05CMP-3 SRK09CMP-3, 09CMP-4 Safety precautions • Please read these “Safety Precautions” first then accurately execute the installation work. • Though the precautionary points indicated herein are divided under two headings,...
Page 28
'13•SRK-T-141 Standard accessories Necessary tools for the installation work (Installation kit) Q’ty Accessories for indoor unit Plus headed driver (Phillips screwdriver) Installation board ① Knife (Attached to the rear of the indoor unit) ② Wireless remote control ③ Remote control holder Tape measure Tapping screws ④...
Page 29
'13•SRK-T-141 Limitations for one way piping length and vertical height difference 15 m One way piping length ( ) Outdoor unit is lower Vertical height difference (h) Outdoor unit is higher Installation of indoor unit Installation of installation board Look for the inside wall structures (Intersediate support or INSTALLATION SPACE (INDOOR UNIT) (FRONT VIEW) fi...
Page 30
'13•SRK-T-141 Preparation of indoor unit Terminal block ① Mounting of connecting wires ⓐ Remove the lid. ⓑ Remove the wiring clamp. ⓒ Connect the connecting wire securely to the terminal block. Use cable for interconnection wiring to avoid loosening of the wires. CENELEC code for cables Required field cables.
Page 31
'13•SRK-T-141 5 Securing the indoor unit to the installation board Indoor unit Installing steps 1. Hook the upper part of the indoor unit to the Installation installation board. board Latch (2 locations) 2. The unit can be installed simply by gently pushing Wall Installation board in the lower part.
Page 32
'13•SRK-T-141 Installation of outdoor unit 1 Make sure that the unit is stable in installation. Fix the unit to stable base. 2 Perfrom wiring, making wire terminal numbers conform to terminal numbers of indoor unit terminal block. Terminal block 3 Earth lead wire shall be longer than the other lead wires for the electrical safety in case of the slipping out of the cord from the anchorage.
[Example] How much amount of additional charge for 15m piping? (15 – 7.5)m × 10g/m=75g 75g for additional charge Models SRK05CM-3, 09CM-3, 09CM-4, 09CM-5 SRK05CMP-3, 09CMP-3, 09CMP-4 When refrigerant piping exceeds 5m conduct additional refrigerant charge after refrigerant sweeping. 5m over 15m:Additional charge amount per meter = 10g/m...
'13•SRK-T-141 Models SRK12CM-3, 12CM-4, 12CM-5 Safety precautions • Please read these “Safety Precautions” first then accurately execute the installation work. • Though the precautionary points indicated herein are divided under two headings, WARNING and CAUTION , those points which are related WARNING section.
Page 35
'13•SRK-T-141 Standard accessories Necessary tools for the installation work (Installation kit) Q’ty Accessories for indoor unit Plus headed driver (Phillips screwdriver) Installation board ① Knife (Attached to the rear of the indoor unit) ② Wireless remote control ③ Remote control holder Tape measure Tapping screws Hammer...
Page 36
'13•SRK-T-141 Limitations for one way piping length and vertical height difference 15 m One way piping length ( ) Outdoor unit is lower Vertical height difference (h) Outdoor unit is higher Installation of indoor unit Installation of installation board Look for the inside wall structures (Intersediate support or INSTALLATION SPACE (INDOOR UNIT) (FRONT VIEW) pillar and ...
Page 37
'13•SRK-T-141 Preparation of indoor unit Terminal block 1 Mounting of connecting wires a Remove the lid. b Remove the wiring clamp. c Connect the connecting wire securely to the terminal block. Use cable for interconnection wiring to avoid loosening of the wires. CENELEC code for cables Required ...
Page 38
'13•SRK-T-141 ⑤ Securing the indoor unit to the installation board Installing steps Indoor unit Installation board 1.Hook the upper part of the indoor unit to the installation board. Installation board Wall 2.The unit can be installed Indoor unit base lower latch simply by gently pushing in the lower part.
Page 39
'13•SRK-T-141 Installation of outdoor unit 1 Make sure that the unit is stable in installation. Fix the unit to stable base. 2 Perfrom wiring, making wire terminal numbers conform to terminal numbers of indoor unit terminal block. 3 Earth lead wire shall be longer than the other lead wires for Terminal block the electrical safety in case of the slipping out of the cord from the anchorage.
Page 40
'13•SRK-T-141 ♦ Additional refrigerant charge When refrigerant piping exceeds 5.0m conduct additional refrigerant charge after refrigerant sweeping. 5.0m over 15m:Additional charge amount per meter = 10g/m [Example] How much amount of additional charge for 15m piping? (15 – 5.0)m × 10g/m=100g 100g for additional charge Insulation of connecting portion 1 Cover the connection portion of the refrigerant piping with the pipe To cover the connecting portion with insulation...
'13•SRK-T-141 7. OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER (1) Operation control function by remote control Remote control Models All model ◆ Operation section FAN SPEED button OPERATION MODE select button Each time the button is pushed, the Each time the button pushed, the indicator is switched over in turn.
Page 42
'13•SRK-T-141 Unit display section Models SRK05CM, 05CM-3 SRK05CMP-3 SRK09CM-3, 09CM-4, 09CM-5 SRK09CMP-3, 09CMP-4 Remote control signal receiver Unit ON/OFF button This button can be used for turning on/off the unit when remote control is not available. Room temperature detector ON/OFF RUN light (green) •...
'13•SRK-T-141 (2) Unit ON/OFF button When the remote control batteries become weak, or if the remote control is lost or malfunctioning, this button may be used to turn the unit on and off. (a) Operation Push the button once to place the unit in the automatic mode. Push it once more to turn the unit off. (b) Details of operation The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by sensor), whether to go into the cooling or thermal dry modes.
'13•SRK-T-141 (7) Outline of cooling operation (a) Operation of major functional components in Cooling mode Cooling Thermostat ON Thermostat OFF Failure Compressor Indoor fan motor Outdoor fan motor (b) Fan speed switching Model All model Fan speed AUTO Auto fan control Speed 6 Speed 4 Speed 3...
'13•SRK-T-141 (9) Protective control function (a) Frost prevention for indoor heat exchanger (During cooling or dehumidifying) (i) Operating conditions Indoor heat exchanger temperature (Th2) is lower than 2.5ºC. 3 minutes elapsed after the start of operation. (ii) Detail of frost prevention operation Compressor Indoor fan Protects the fan tap just before frost prevention control.
'13•SRK-T-141 8. MAINTENANCE DATA (1) Cautions (a) If you are disassembling and checking an air conditioner, be sure to turn off the power before beginning. When working on indoor units, let the unit sit for about minute after turning off the power before you begin work. When working on an outdoor unit, there may be an electrical charge applied to the main circuit (electrolytic condenser), so begin work only after discharg- ing this electrical charge (to DC 0 V or lower).
'13•SRK-T-141 (4) Troubleshooting procedure (If the air conditioner runs) Confirm the contents of the customer complaint. The cause of the trouble can be specifically identified. Eliminate the cause of the trouble and perform an Check the self-diagnosis display. operation check. See below.
'13•SRK-T-141 (6) Inspection procedures corresponding to detail of trouble Sensor error [Broken sensor wire, connector poor connection] Is connector connection good? Correct connection. Is sensor resistance value good? Replace sensor. Replace PCB. ◆ Sensor temperature characteristics (Room temp., indoor heat exchanger temp.) (Broken wire) (Short circuit) - 10...
Page 50
'13•SRK-T-141 Trouble of outdoor unit [Compressor malfunction of insufficient gas (refrigerant)] Replace capacitor for compressor. Does compressor operation? Is capacitor for compressor normal? Is connector for compressor connection Correct connection good? Replace compressor. Check if there are any places where Is refrigerant amount normal? Does trouble persist after charging gas? gas is leaking...
Page 51
'13•SRK-T-141 (8) How to make sure of wireless remote control Is remote Remote control control normal? defects Replace the display of indoor unit. Again pushing operating switch Is the unit Normal operable with remote control? Abnormality is not Operating the unit? found.
Page 52
'13•SRK-T-141 PARTS LIST TECHNICAL MANUAL INDOOR UNIT SRK05CM , SRK05CM-3 SRK05CMP-3 SRK09CM-3 , SRK09CM-4, SRK09CM-5 SRK09CMP-3 , SRK09CMP-4 SRK12CM-3, SRK12CM-4, SRK12CM-5 OUTDOOR UNIT SRC05CM , SRC05CM-3 SRC05CMP-3 SRC09CM-3 , SRC09CM-4, SRC09CM-5 SRC09CMP-3 , SRC09CMP-4 SRC12CM-3, SRC12CM-4, SRC12CM-5...
Page 53
'13•SRK-T-141 PANEL & FAN ASSY CRAE0268...
Page 97
RESIDENTIAL AIR-CONDITIONING TECHNICAL MANUAL & PARTS LIST Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice. Copyright MITSUBISHI HEAVY INDUSTRIES, LTD.
Need help?
Do you have a question about the SRK05CM and is the answer not in the manual?
Questions and answers
Lamp run blinking, lamp timer still on
When the lamp is blinking on a Mitsubishi Heavy Industries SRK05CM unit while the TIMER light is still on, it indicates a trouble condition. Specifically:
- If the RUN light blinks once and the TIMER light is ON, it means a heat exchanger sensor error (e.g., sensor wire disconnection or temperature ≤ –28ºC for 15 seconds).
- If the RUN light blinks twice and the TIMER light is ON, it indicates a room temperature sensor error (e.g., wire disconnection or temperature ≤ –45ºC for 15 seconds).
This signals the unit has stopped due to a detected fault.
This answer is automatically generated