Yamaha AD824 Service Manual page 37

Hide thumbs Also See for AD824:
Table of Contents

Advertisement

(5) Noise level EIN
Conditions: CH IN 1 to 8 channels shorted using 150 ohms.
GAIN
-62 dB
However, if it does not enter within the permissible range shown above, the measured value shall be (gain per 1 kHz) ≤ -128.
(6) Difference between channels
Specify so that it will be less than the difference in the gain range measured at (1).
Permissible range
Within 1 dB
(7) Cross talk between odd channels and even channels
Conditions: Input signal into odd channels.
Even channels shorted using 150 ohms.
Input frequency
1 kHz
Even channels are also the same.
(8) Phantom
Short XLR pin 2 and pin 3, connect a 10 kohms load between pins 2 and 1 and measure the voltage as shown below when the
+48V master switch is turned on.
Permissible range
DC34 to 38V
Check that discharge starts quickly when the +48V master switch is turned off and when the [+48] key is set to off.
2-2
INSERT IN1 to 8CH
(1) Maximum input
Input frequency
1 kHz
2-3
INSERT OUT1 to 8CH
Conditions: The load for AD824 insert out 1 to 8 channels is 10 kohms.
(1) Maximum input
Input frequency
1 kHz
2-4
Operation confirmation of level meters 1 to 8
Conditions: Input specified level to AD824 input 1 to 8.
AD824 can also have simultaneous input of channels 1 to 8
Visually confirm the on and off of the peak, nominal and signal LEDs.
(1) On (Lit)
LED level
PEAK
NOMINAL
SIGNAL
(2) Off (Not lit)
LED level
PEAK
NOMINAL
SIGNAL
2-5
Jitter measurement
(1) INTERNAL 44.1 kHz, 48 kHz
· Insert MY8-AE card into the slot and connect to DSA1 via the D-sub-cannon converter box.
· Set AD824 word clock settings to 44.1 kHz and 48 kHz.
WORD CLOCK
44.1 kHz
48 kHz
Permissible range
Less than -62 dBu
Output level (Odd CH) Permissible range (Even CH)
Less than -54 dBu
+16 dBu
Input level
Specified output level (DA824)
+24 dB
Input level
Specified output level (AD824)
+24 dB
Input frequency
Input level
1 kHz
1 kHz
1 kHz
Input frequency
Input level
1 kHz
1 kHz
1 kHz
Permissible range
Less than 5 nsec
Less than 5 nsec
Permissible range
+18 dBu
18 +/-1 dBu
Permissible range
+24 dBu
24 +/-1 dBu
Reference output level (DA824)
+23 dBu
+17 dBu
+12 dBu
+6 dBu
-8 dBu
-14 dBu
Reference output level (DA824)
+18 dBu
+12 dBu
+8 dBu
+2 dBu
-12 dBu
-18 dBu
AD824