Arming with the Keyfob
To arm the system using the keyfob:
Press the relevant button on your keyfob (see Keyfobs); the exit delay
begins to count down. At the end of the exit delay, the system
is armed.
Arming with the Key Switch
To arm the system using a key switch:
Open/close the key switch accordingly.

Forced Arming

Forced arming enables you to arm when the system is not ready. For example, if a door
protected by a magnetic contact is open, you may arm the system on condition that the
door will be closed by the end of the Exit delay. If the door is still open after the exit
delay expires, an alarm is generated.
Forced arming is available only if the option is enabled in programming. Forced arming
may be enabled for specific zones or for the entire system.

Instant Arming

Instant arming is a feature that allows you to cancel the entry delay after Part or
Perimeter arming the system. For this feature to function, it must be enabled in
programming by your installer.
To instantly arm the system.
1.
Check if the system is ready to arm.
2.
Press the Part or Perimeter arming key on the keypad and enter your user
code if One-Key Arming is disabled.
3.
Press and hold down
OK? is displayed
4.
Press ; the entry delay for the current arming period is canceled.
Supervised Arm
Supervised Arm is an optional feature designed to supervise intrusion detector activity
before you arm the system.
If supervised arm is enabled in programming and the system has not received a
transmission from a detector for a certain amount of time, all arming methods that
include that detector shall not be available.
In this case, press
condition.
To make the required arming method available, activate the detector. If activating the
detector does not help, there may be a problem with the detector. You can bypass the
faulty detector's zone to allow system arming until the problem is remedied – see Zone
Bypassing/Unbypassing.
on your keypad until the message Instant Arming,
to check which detector is causing the "System Not Ready"