4.3 Power Supply Requirements
A/C Line voltage range
A/C Line frequency range
Current
Peak surge current
Leakage current
Power line surge
: 100 V ~ 240 V
: 50 ± 3Hz, 60 ± 3Hz
: 1.5A max. at 100V, 0.8A max. at 264V
: < 55A peak at 240 VAC and cold starting
: < 3.5mA
: No advance effects (no loss of information or defect) with
a maximum of 1 half-wave missing per second