WHAT TO DO IN CASE OF A FIRE

1. Don't panic; stay calm.
2. Leave the building as quickly as possible. Touch doors to feel
if they are hot before opening them. Use an alternate exit if
necessary. Crawl along the floor, and DO NOT stop to collect
anything.
3. Meet at a pre-arranged meeting place outside the building.
4. Call the fire brigade (Dial 999) from OUTSIDE the building.
5. DO NOT GO BACK INSIDE A BURNING BUILDING. Wait for
the fire brigade to arrive.
These guidelines will assist you in the event of a fire. However, to
reduce the chance that fires will start, practice fire safety rules and
prevent hazardous situations
DANGER:
!
WARNING:
!
PROBLEM
Smoke alarm does not
sound when tested.
NOTE: Push and hold
test button for at least
five (5) seconds while
testing!
Smoke alarm beeps
once every 40 seconds
(KF10 and KF20 only)
(KF10R and KF20R )
item #3
Smoke alarm sounds
unwanted alarms when
residents are cook-
ing,taking showers, etc.
Interconnected smoke
alarms do not sound
when system is tested.
3 chirps every 40
seconds

TROUBLESHOOTING

Always turn off power at main fuse box or
consumer unit before taking trouble-shooting
action.
DO NOT disconnect battery or mains power
to quiet an unwanted alarm. This will remove
your protection. Fan the air or open a win-
dow to remove smoke or dust. For Models
KF10, KF10LL, KF10R, KF20, KF20LL and
KF20R you may also use the Hush Button
feature to quiet unwanted alarms.
1. Check that AC power is
2. Turn off power. Remove
a. check that connector plug
b. check that battery is
3. Clean smoke alarm.
1. Turn off power and replace
2. Clean smoke alarm.
3. Verify that unit has been
1. Hire an electrician to move
1. Press and hold test button
2. Hire an electrician to
Ten (10) year end of life warn-
ing. Alarm must be replaced
(REPLACE IMMEDIATELY! )
7
SOLUTION
turned on. Green LED
should be illuminated.
smoke alarm from mount-
ing plate and:
is securely attached.
properly attached to con-
nector.
battery. See in the MAINTE-
NANCE AND CLEANING
section.
under mains operation for a
minimum of 2 full days. If
the beeping persists after
required charging period,
return the unit for service.
smoke alarm to a new
location. See "SMOKE
ALARM PLACEMENT".
for at least three seconds
after the first unit sounds.
ensure smoke alarms are
properly connected.