1374-7205-00(KF10_KF20_KF10R_KF20R)_EN_V4:_
replace with (N) mains power cable.
4. Connect brown cable from connector plug of smoke alarm to live (L)
mains power cable.
5. If interconnection is desired, connect orange or white cable from con-
nector to interconnect strand on the 3 core & earth cable. See section,
"Interconnecting Smoke Alarms."
NOTE:
If this will be a single-station smoke alarm, cover orange or white
DRY LINING BOX
MODELS KF10, KF10LL,
KF20, KF20LL
cable with electrical tape and tuck into pattress.
Steps 6-9 for Models KF10, KF10LL, KF20, KF20LL ONLY:
6. Lift open battery pocket door.
7. Connect new 9-volt battery to battery connector inside battery pocket. BE
SURE BATTERY IS SECURELY CONNECTED. Smoke alarm may beep
briefly when battery is installed.
8. Close battery pocket door, snapping it into place.
9. KF10LL and KF20LL include a tamper-proofing locking option, using
the screw provided
10. Push button and hold button on front cover of smoke alarm for three
(3) seconds. Smoke alarm should sound its alarm horn if battery is fit-
ted correctly.
11. Attach connector plug to pins on back of smoke alarm. Plug will only
fit one way and will snap into place.
12. Gently tug connector to be sure it is attached securely.
13. Position smoke alarm to mounting plate so that keyslot on side of
smoke alarm is to left of tab on mounting plate. Turn clockwise to lock
place.
into
NOTE: (For Models KF10, KF10LL, KF20 and KF20LL only):
Smoke alarm will not mount to plate if battery is not installed.
14. Turn on power at main fuse box or circuit breaker. The green LED on the
cover should be illuminated.
15. Test smoke alarm. See "TESTING THE SMOKE ALARM".
2
Use 1.5mm
When interconnecting, maximum cable length between any two is 450
m for 1.5mm
NOTE: Maximum length under BS7671 17th Edition wiring regs
amendment 1 for CB/RCBO type B is 72 metres for TN-S or TN-C-S
systems (source "On-Site Guide" page 59)
This smoke alarm may be interconnected with as many as 23other
Models smoke alarms, as listed on page 1. DO NOT connect to any
other type or model smoke alarm.
Connect smoke alarms to a single circuit. Wiring must conform to IEE
ORANGE OR WHITE
FOR INTERCONNECT: USE STANDARD 3 core & earth cable 1.5mm2 cable
Regulations for electrical installation.
This smoke alarm features red and green LED indicators that can be seen
through the Push-to-Test button or the LED lens above the test button.
The LEDs indicate the following:
GREEN LED
ON —
AC power is present
OFF —
AC power is not present.
RED LED
Blinks once every 5 minutes AND 20 SECONDS —
OR PATTRESS
CEILING
MODELS KF10R, KF20R (Rechargeable)
INTERCONNECTING
SMOKE ALARMS
minimum solid or stranded cable with a rating of 230V.
2
or 1200 m for 2.5mm
ORANGE OR WHITE
RED AND GREEN LED
INDICATORS
.
DRY LINING BOX
OR PATTRESS
2
(20 OHMS loop resistance).
indicating normal
operation.
4
2014.11.20
CEILING
NEUTRAL
LINE
10:16 A