3. OPERATION RANGE

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING
INDOOR
OUTDOOR
TEMPERA-
UNIT
TURE
D
18 to 37
B
RZQS71 · 100 ·
125
W
12 to 28
B
HEATING
INDOOR
OUTDOOR
TEMPERA-
UNIT
TURE
RZQS71 · 100 ·
D
10 to 27
125
B
D B: Dry bulb temperature
WB: Wet bulb temperature
The setting temperature range of the control panel is
16°C to 32°C.

4. INSTALLATION SITE

Regarding places for installation
• Is the air conditioner installed at a well-ventilated
place where there are no obstacles around?
• Ensure that the remote controller is not
exposed to direct sunlight.
This will cause discoloration of the LCD dis-
play with resulting loss of readability.
• Do not use the air conditioner in the following
places.
a.Filled with much mineral oil such as cutting oil
b.Where there is much salt such as a beach area
c.Where sulfured gas exists such as a hot-spring
resort
d.Where there are considerable voltage fluctua-
tions such as a factory or plant
e.Vehicles and vessels
f .Where there is much spray of oil and vapor such
as a cookery, etc.
g.Where there are machines generating electro-
magnetic waves
h.Filled with acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For details, consult your dealer.
4
[°C]
OUTDOOR
TEMPERA-
HUMI-
TURE
DITY
80%
D
or
–15 to 50
B
below
[°C]
OUTDOOR
TEMPERA-
TURE
D
–19.5 to 21
B
W
–20 to 15.5
B
Regarding wiring
• All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by yourself.
• Make sure that a separate power supply circuit
is provided for this air conditioner and that all
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.
Pay attention to running noises, too
• Are the following places selected?
a.A place that can sufficiently withstand the
weight of the air conditioner with less running
noises and vibrations.
b.A place where the hot wind discharged from the
air outlet of the outdoor unit and the running
noises do not bother your neighbors.
• Are you sure that there are no obstacles near
the air outlet of the outdoor unit?
Such obstacles may result in declined perfor-
mance and increased running noises.
• If abnormal noises occur in use, consult your
dealer.
Regarding drainage of drain piping
• Is the drain piping executed to perform com-
plete drainage?
If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation,
chances are that dust and dirt are clogged in the
pipe. This may result in a water leakage from the
indoor unit. Under such circumstances, stop the
operation of the air conditioner, and then consult
your dealer or our service station.
5. NAME AND FUNCTION OF EACH
SWITCH AND DISPLAY ON THE
CONTROL PANEL
Refer to figure 1 on page [1]
ON/OFF BUTTON
1
Press the button and the system will start.
Press the button again and the system will stop.
OPERATION LAMP (RED)
2
The lamp lights up during operation.
DISPLAY "
(UNDER CENTRALIZED CONTROL)
3
When this display shows, the system is
UNDER CENTRALIZED CONTROL.
(This is not a standard specification.)
"
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fvq125bv1bFvq100bv1b

Table of Contents