  • Page 1 Automatic Digital and Manual Humidifier Control Models 60, 62 & 4655 Operating Instructions INSTALLER: Please leave this Operation anual with the homeowner.
  • Page 2 Change Water Panel: The yellow light indicates that it is time Communicating Thermostat, and the blower activation feature is to change the Water Panel in the humidifier. (Model 60 only. The desired, DO NOT wire the A B communication terminals.
  • Page 3 HVAC blower is operating. 90-1235B Your Aprilaire Humidifier Control is installed in the cold air return duct. During the first heating season, your Humidifier Control needs to be set initially to match your home’s condition. Please follow these steps when adjusting your control (refer to Figure A).
  • Page 4 MANUAL MODE (Automatic Mode – see page 5) See Table 1 for the recommended settings. These settings, which are based on years of research, represent a compromise between humidity levels that would be most desirable for Figure B – Manual Mode comfort and humidity levels that are suitable for protection of your home and to avoid condensation on your windows.
  • Page 5 WATER PANEL CHANGE INDICATOR (MODEL 60 ONLY) ADDITIONAL INFORMATION The control keeps track of humidifier operation time. The yellow Your humidifier is a precision system that will accurately “Change Water Panel” light flashes after a preset amount of maintain the humidity in your home. For every 2°F change in running time has elapsed.
  • Page 6 90-1237 Humidifier won’t shut off. Turn dial to “Off”. If unit continues to Your Aprilaire humidifier is controlled by a Manual Humidifier operate, consult a heating contractor. Control (see Figure C). The Manual Humidifier Control is Test mode. System operation is checked by setting installed either in the cold air return duct or on an interior wall of the knob to “Test/Reset”.
  • Page 7 Check the Humidifier Operation Annual Summer Shutdown Digital Humidifier Control in Automatic Mode (see Figure A) DIGITAL HUMIDIFIER CONTROL and Blower Activation switch is in the ”OFF” position: Set the knob to “Test/Reset”, make sure that the water saddle No adjustment is necessary. valve is open and that there is electricity to the humidifier.