The Go!Bridge IP Communicator™ (2GIG‐BRDG1‐900) provides Internet 
connectivity between the monitoring service's Central Station and the 
Go!Control® Panel, when the panel is used as a household burglar alarm 
system. 
It supports automatic firmware updates, provides interactive security 
services, and increases supervision using signal‐forwarding to the Central 
Station. For wireless communication with the Control Panel, the 900MHz 
Transceiver Module (2GIG‐XCVR) must be installed in the panel. For 
Internet access, the Go!Bridge must be connected to the local network 
router using an Ethernet cable (not provided).
Contents
Verify that the package includes the following:
1—Go!Bridge IP Communicator 
1—5VDC USB Mini‐B Power Supply
1—Stand
1—Plastic Power Supply Bracket (includes Self‐Adhesive Backing 
and Zip Tie)
1—Wall Socket Screw for Power Supply Bracket
2—Phillips Head Screws and Wall Anchors (to mount unit on wall)
4—Self‐Adhesive Vinyl Bumpers for use on unit or stand
Requirements
Before you install, program, and test the Go!Bridge IP Communicator, 
ensure the control panel being paired with the Go!Bridge IP 
Communicator meets these requirements:
Firmware Version 1.12 (or higher)
2GIG‐XCVR 900 MHz Transceiver
For compliance with UL 1023: Household Burglar‐
IMPORTANT:
Alarm System Units, the Go!Bridge must be installed in the 
same room as the Internet modem or router.
NOTE: To protect data sent via the local wireless network, it is 
recommended that you install the Go!Bridge IP Communicator on 
a local network where either WPA (Wi‐Fi Protected Access) or 
WPA2 (Wi‐Fi Protected Access II) encryption is already enabled.
After installing, programming, and testing the Go!Bridge IP 
Communicator, you will need to register a new customer with the third‐
party monitoring service. See Registration on page 3.
Figure 1 Go!Bridge Front View—LED Indicators and Learn Button
A Network LED
B 900 MHz LED
C Learn Button
Powering ON the Go!Bridge IP Communicator
Use these steps to power ON the Go!Bridge IP Communicator:
1
Attach the power supply to the bracket (provided) as follows:
1a Insert the power supply into the enclosure on the plastic bracket. 
See C in the figure below.
1b Secure the power supply to the retaining bracket by threading a 
zip tie through the bracket's slots. See D in the figure below. 
1c Remove the strip from the self‐adhesive backing on the power 
supply bracket.
1d Affix the adhesive on the bracket to the wall outlet. Then secure 
the bracket to the outlet with the wall socket screw (provided). 
NOTE: Always use the provided power supply bracket in the United 
States (and other countries where it is required). Canada does not 
require the power supply retaining bracket.
Figure 2 Power Supply and Bracket
A 110V Wall Outlet
B
Plastic Power Supply Bracket with Adhesive Backing
C
AC Power Supply
D Zip Tie
2
Connect the Go!Bridge to the power source. 
NOTE: Do not connect an Ethernet cable to the Go!Bridge IP 
Communicator at this time. You will connect the cable when 
completing the steps in Programming the Go!Bridge IP 
Communicator into the Control Panel.
3
(Optional) Place the stand (provided) on a counter, desktop, or other 
flat surface. Set the Go!Bridge IP Communicator in the stand. 
NOTE: To protect surfaces from damage, affix the self‐adhesive vinyl 
bumpers to the unit or stand. 
4
Verify that the two (2) LEDs on the Go!Bridge IP Communicator 
illuminate in RED. See Figure 1  Go!Bridge Front View—LED Indicators 
and Learn Button on page 1. 
Copyright © 2014 Linear LLC
1

Advertisement

loading

Summary of Contents for 2gig Technologies 2GIG-BRDG1-900

  • Page 1: Installation Instructions

    2GIG-BRDG1-900 GO!BRIDGE IP COMMUNICATOR INSTALLATION INSTRUCTIONS Powering ON the Go!Bridge IP Communicator Use these steps to power ON the Go!Bridge IP Communicator: The Go!Bridge IP Communicator™ (2GIG‐BRDG1‐900) provides Internet  Attach the power supply to the bracket (provided) as follows: connectivity between the monitoring service’s Central Station and the  Go!Control® Panel, when the panel is used as a household burglar alarm  1a Insert the power supply into the enclosure on the plastic bracket.  system.  See C in the figure below. It supports automatic firmware updates, provides interactive security  1b Secure the power supply to the retaining bracket by threading a  services, and increases supervision using signal‐forwarding to the Central  zip tie through the bracket’s slots. See D in the figure below.  Station. For wireless communication with the Control Panel, the 900MHz  1c Remove the strip from the self‐adhesive backing on the power  Transceiver Module (2GIG‐XCVR) must be installed in the panel. For  supply bracket. Internet access, the Go!Bridge must be connected to the local network  1d Affix the adhesive on the bracket to the wall outlet. Then secure  router using an Ethernet cable (not provided). the bracket to the outlet with the wall socket screw (provided).  Contents NOTE: Always use the provided power supply bracket in the United  States (and other countries where it is required). Canada does not ...
  • Page 2: Led Indicators

    Go!Bridge IP Communicator | Installation Instructions NOTE: If the 900MHz LED illuminates in GREEN (the lower LED),  At Q: Network Device ID (Read Only), tap Learn. This gives the  verify that the network cable is not connected to the Go!Bridge  panel the ability to discover the read‐only network device ID  IP Communicator. If the cable is disconnected and it is still  transmitted by the Go!Bridge IP Communicator. illuminated GREEN, use the end of an open paperclip to press  At the Pair with Xcvr Device screen, the “initiating learning  and release the recessed Reset button. The button is located  process” message appears. inside the small hole on the port side of the Go!Bridge IP  10 On the Go!Bridge IP Communicator, press and release the Learn  Communicator, directly above the Ethernet port. This restores  button (this is the small, black plastic button on the LED side of the  the factory settings. See Figure 3  Go!Bridge IP Communicator  Go!Bridge IP Communicator below the 900MHz LED). This transmits  Rear View—Ports and Recessed Reset Button. the device ID to the Control Panel.  — Figure 3 Go!Bridge IP Communicator Rear View Ports and When the “learn operation succeeded” message appears and the  panel displays the Type (Go!Bridge IP Communicator) and ID#, the  Recessed Reset Button Go!Bridge IP Communicator and panel are linked. The 900MHz LED ...
  • Page 3: Regulatory Information

    Go!Bridge IP Communicator | Installation Instructions Verifying the Settings REGULATORY INFORMATION In addition to verifying the settings after configuring the Go!Bridge IP  Communicator, you can also verify the settings at any time as follows: At the Control Panel’s Home screen, tap Security. Tap Menu. Tap Toolbox. In the Enter Your Code to Access the Toolbox screen, enter the  master user code.  Tap → to scroll to the Toolbox (3 of 3) screen. Then tap Go!Bridge  IP Communicator Status. A summary screen displays the following information: • Network Configuration. The network type configuration. Wireless Product Notice • IP Address. The IP Address for the Go!Bridge IP Communicator.  This is a 32‐bit numeric address that identifies the device on the  Radio controls provide a reliable communications link and fill an  network. important need in portable wireless signaling; however, there are some  • Subnet Mask. The subnet mask for the network. All devices that  limitations which must be observed. are joined to a network belong to a subnetwork. • For United States Installations Only: The radios are required to  • Gateway. The IP Address for the access point to the external  comply with FCC Rules and Regulations as Part 15 devices. As ...
  • Page 4: Limited Warranty

    Go!Bridge IP Communicator | Installation Instructions Industry Canada (IC) Compliance LIMITED WARRANTY This device complies with Industry Canada license‐exempt RSS  This Linear product is warranted against defects in material and  standard(s). Operation is subject to the following two conditions: (1)  workmanship for two (2) years. This warranty extends only to wholesale  this device may not cause interference, and (2) this device must accept  customers who buy direct from Linear LLC or through Linear LLC’s  any interference, including interference that may cause undesired  normal distribution channels. Linear LLC does not warrant this product  operation of the device. to consumers. Consumers should inquire from their selling dealer as to  Repairs to certified equipment should be made by an authorized  the nature of the dealer’s warranty, if any.  Canadian maintenance facility designated by the supplier. Any repairs or  There are no obligations or liabilities on the part of Linear LLC for  alterations made by the user to this equipment, or equipment consequential damages arising out of or in connection with use or  malfunctions, may give the telecommunications company cause to  performance of this product or other indirect damages with respect to  request the user to disconnect the equipment. loss of property, revenue, or profit, or cost of removal, installation, or  reinstallation. All implied warranties for functionality, are valid only  Users should ensure for their own protection that the electrical ground  until the warranty expires. This Linear LLC Warranty is in lieu of all other  connections of the power utility, telephone lines and internal metallic  warranties expressed or implied. water pipe system, if present, are connected together. This precaution  may be particularly important in rural areas. WARNING: Users should not attempt to make such connections  themselves, but should contact the appropriate electric ...