Ptt Frequency Drop Down Menu; Guard Tone Duration Field; Guard Tone Magnitude Field; Hold Tone Magnitude Field - Telex IP-223 Technical Manual

Remote adapter panel
Hide thumbs Also See for IP-223:
Table of Contents

Advertisement

Tone Frequency & Durations Window
Guard Hold

PTT Frequency Drop Down Menu

The PTT Frequency drop down menu, shown in Figure 77, identifies the PTT frequency, in Hz, the console uses.
Available selections for this field are 2100, 2175, 2300, 2325, 2400, 2600, 2800, 2850 and 2970Hz.
PTT Frequency Drop Down Menu
FIGURE 77.

Guard Tone Duration Field

The Guard Tone Duration field identifies the amount of time, in ms, the guard tone plays before the function tone.
The range for this field is 0 to 999ms.

Guard Tone Magnitude Field

The Guard Tone Magnitude field identifies the level, in dBm, of the guard tone.
The range for this field is -60 to 12dB.

Hold Tone Magnitude Field

The Hold Tone Magnitude field identifies the level, in dBm, of the hold tone summed with TX audio to keep the radio in a
transmit state.
The range for this field is -60 to 12dB.

Hold Tone Hangtime Field

The Hold Tone Hangtime field identifies the amount of time, in ms, the hold tone continues after the release of the PTT
button. Pressing the PTT button again during this hangtime continues the transmission without resending the guard and
function tones.
The range for this field is 0 to 999ms.