Resistance values in orms ( ).
V: Voltmeter or oscilloscope
(r.m.s. or peak reading)
Input resistance :
1 M
Input capacitance :
200 pF
Frequency range : 15 Hz to 1 MHz and d.c. respectively
Note: Appropriate measures should be taken to obtain the correct value in case of non
sinusoidal waveforms.
The measuring instrument is calibrated by comparing the frequency factor of
solid line in figure F.2 of IEC 60990 at various frequencies. A calibration curve is
constructed showing the deviation of
from the ideal curve as a function of frequency.
TOUCH CURRENT =
/500 (peak value).
The potential at any point (TOUCH CURRENT) expressed as voltage
does not exceed the following value:
The part or contact of a TERMINAL is not HAZARDOUS LIVE if:
a) The open-circuit voltage should not exceed 35 V (peak) a.c. or 60 V d.c. or, if a) is not
met.
b) The measurement of the TOUCH CURRENT shall be carried out in accordance with
IEC 60990, with the measuring network described in Annex D of this standard.
The TOUCH CURRENT expressed as voltages
following values:
- for a.c. :
= 35 V (peak) and
= 0.35 V (peak);
- for d.c. :
= 1.0 V
Note: The limit values of
= 0.35 V (peak) for a.c. and
the values 0.7 mA (peak) a.c. and 2.0 mA d.c.
with the
and
and
, does not exceed the
= 1.0 V for d.c. correspond to