Service Adjustments - Sharp LC-32GA8 Service Manual

Table of Contents

Advertisement

The adjustment values are set to their optimum at the factory before shipping. If by any chance a value should become im-
proper or a readjustment is required due to part replacement, make an adjustment according to the following procedure.
1. Entering and exiting the adjustment process mode
1- Unplug the AC power cord of TV set to force power off.
2- While holding down the "VOL (–)" and "INPUT" keys on the set at once, plug in the AC power cord to turn on the
set. The letter K appears on the screen. (Factory mode)
3- Next, hold down the "VOL (—)" and "P ( V )" keys on the set at once. Multiple lines of orange characters appearing
on the screen indicate that the set is now in the adjustment process mode. If you fail to enter the adjustment process
mode (the display is the same as normal start up), retry the procedure.
4- To exit the adjustment process mode after the adjustment is done, unplug the AC power cord to force off the
power. (When the power is turned off with the remote controller, once unplug the AC power cord and plug it in
again. In this case, wait 10 seconds plugging.)
5- To remove "K" mode holding down the "VOL (–)" and "INPUT" keys on the set at once ("K" disappears).
Caution: Use due care in handling the information described here lest the users should
know how to enter the adjustment process mode. If the settings tampered with in
this mode, unrecoverable system damage may result.
2. Remote Controller Key Operation and Description of Display in Adjustment Process Mode
2.1 Key operation
Remote controller key
P (Λ / V)
VOL (+/-)
Cursor (UP / DOWN)
Cursor (LEFT / RIGHT)
INPUT SOURCE
on remote controller
OK
Input mode is switched automatically when relevant adjustment is started so far as the necessary input signal
available.
2.2 Description of display
Current page/ Total pages
1/11
Main Version
Dev Version
Dev Loader Version
Pic Version
TEMP SENSOR
NORMAL STANDBY CAUSE
ERROR STANDBY CAUSE

SERVICE ADJUSTMENTS

Main unit key
Function
P (Λ / V)
Moving an item (line) by one (UP/DOWN)
VOL (+/-)
Changing a selected item setting (+1/-1)
————
Turning a page (PREVIOUS / NEXT)
————
Changing a selected line setting (+10/-10)
INPUT button
Input source switching (toggle switching)
(TV → EXT1 → EXT2 → EXT3 → EXT4 → EXT5)
(Not Operative)
————
Executing a function
Current page title
[INFO]
TV
LEW05 01.XXXX (YYYY/MM/DD X) X
_ _ _ _ _
_ _ _ _ _
XX.XX
XXX
XXXXX
[1] 0
[2] 0
[3] 0
[4] 0
[5] 0
Currently selected input
Current color TV system
Inch Setting
Destination
it may be EURO, UK, ITALY, FRANCE or RUSSIA)
AUTO
32: EURO
XXHXXM
XXHXXM
XXHXXM
XXHXXM
XXHXXM
15
LC-26GA5E
LC-32GA8/LC-32BV8
LC-32GA5E
LC-37GA8/LC-37BV8
(32 just as example, it may be: --/32/37)
(EURO just as example. See Factory Init,
Adjustment process menu
header
Parameters

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-32bv8Lc-37ga8Lc-37bv8