12. Technical Specifications
Model Name
HR85
Detection Method
Active Infrared Reflection
Installation Height
2.0
4.0m
Mounting Height adjustment
2
3m / 2.5
4m (Dip Switch)
Sensitivity adjustment
H / M / L / Snow (Dip Switch)
Adjustable Angle
10 (Area Adjusting Screw)
Depth adjustment
Row
6R / 5R / 4R / 3R / 2R (Dip Switch)
Adjustable Angle
10 (1 Step)
Wide / Narrow (Area Mask)
Width adjustment
Adjustable Area 1
Adjustable Area 2
Wideness (with Prism)
Self-Monitoring
ON / OFF (Dip Switch)
st
1
Row Detection
Doorway / Normal (Dip Switch)
Supply Voltage
AC/DC 12
24V
10%
AC12V : 2.3VA Max
Power Consumption
AC24V : 2.9VA Max
Output
Relay Contact 1a DC50V 0.1A Resistance load
Output Holding Time
Approx. 0.5 seconds
2s / 10s / 60s /
(Dip Switch)
Presence Timer
(Set to 2s / 10s / 60s : 6 rows set at the same time.)
(Set to
the period is infinity in case of the 1
Frequency
6 Frequencies (Dip Switch)
Power Indicator LED : <Power-ON> ON / <2nd Row Overlapped & Self-Monitoring> BLINK
LED Indicator
Operation Indicator LED : <Detection> ON / <2nd Row Overlapped & Self-Monitoring> BLINK
Initialization Indicator LED : <During Initialization> ON / <Adjustment Mode> BLINK
Operating Temperature
-20
+60
Weight
Approx. 310 g
Please note that specifications are changed without notice.
13. External Dimensions
150
< Disclaimer > The manufacturer cannot be held responsible for below.
1. Misinterpretation of the installation instructions, miss connection, negligence, sensor modification and inappropriate installation.
2. Damage caused by inappropriate transportation.
3. Accidents or damages caused by fire, pollution, abnormal voltage, earthquake, thunderstorm, wind, floods and other acts of providence.
4. Losses of business profits, business interruptions, business information losses and other financial losses caused by using the sensor or malfunction of
the sensor.
5. Amount of compensation beyond selling price in all cases.
Manufacturer
SALES Europe
HOTRON CO.,LTD.
Hotron Ireland Ltd.
1-11-26 Hyakunin-Cho, Shinjuku-Ku, Tokyo, Japan
26 Dublin Street (2nd Floor), Carlow, Ireland
Phone:
+81-(0)3-5330-9221
Phone:
Fax:
+81-(0)3-5330-9222
Fax:
URL: http://www.hotron.com
URL: http://www.hotron.com
DC12V : 120mA Max
DC24V : 60mA Max
st
nd
rd
, 2
, 3
Row, 2 seconds in case of the 4
Thickness
0.1 34
16.6
58.5
(Unit mm)
+353-(0)59-9140345
+353-(0)59-9140543
MP-10169-A
-8-
User Manual
WARNING
Disregarding this symbol may result in serious injury or death.
CAUTION
Disregarding this symbol may result in injury or damage to equipment.
1. Features
The detection area is made up of 6 rows, each of which has 12 detection spots. This provides a very dense detection area of 72 detection spots.
Using prisms makes it possible to detect wider area. (Mount less than 2.8m in case of using prisms.)
Doorway detection can be set. Either doorway detecting mode or usual activation mode can be selected by Dip Switch.
Under usual activation mode, detection area depth is enlarged.
Angle activation area is adjustable by Area Adjusting Screw not by the way of click.
The narrow/wide area can be adjusted by Area Mask.
6 frequency setting to avoid cross interference between sensors in close proximity.
The sensor is microprocessor controlled, providing programmable Presence Timer. (2, 10, 60 seconds,
If set to
, the period is infinity in case of the Inner 3 Row.
AC/DC 12 24V is applied as Supply voltage.
2. Description
th
th
th
, 5
, 6
Row.)
Ceiling Mounting Plate
Screen
Area Adjusting Screw
Front Panel
Initialization Indicator LED (Red)
Dip Switch
3. Mounting Precaution
CAUTION
Mount the sensor by following information below.
1. Mount between 2.0 4.0m. Mount less than 2.8m
in case of using Prisms.
4. Do not mount in an area where reflection of
sunlight will shine on unit.
'14
Motion & Presence
HR85
Sensor
<Ceiling Internal Mounting Type>
We would like to extend our thanks to you for purchasing this sensor.
Before install this sensor, please read the following instructions carefully.
Body
Dip Switch
Y
Manual Seal
Connector
DOOR SIDE
Operation Indicator LED (Red)
Power Indicator LED (Red)
Y
Dip Switch
Y
X
2. Do not leave any objects which may move
in the Detection Area.
2.0 4.0m
5. Do not mount in humid or steamy
environment.
-1-
)
Y
<Accessories>
Fixing Screw
Mounting Template
User Manual
Area Mask
Adjusting
Knob
Connection Cable
<Option>
Prism
(2 pieces)
3. Do not mount where rain or snow can fall
directly on unit.
6. Use different frequency settings for sensors in
close proximity. (Maximum 6 sensors)
Need help?
Do you have a question about the HR85 and is the answer not in the manual?
Questions and answers