Kenwood CKDC-MP576 Service Manual page 6

Cd receiver
Table of Contents

Advertisement

CKDC-MP576
CKDC-MP676F/MP676V
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
60
TUN FANC OUT
61
PON FM
62
VCC2
63
NC
64
VSS
65
MUTE
66
PWIC SVR
67
PWIC STBY
68
PWIC MUTE
69~74
NC
75
RDS CLK
76
TUN TYPE1
77
TUN TYPE2
78
TYPE1
79
TYPE2
80
TYPE3
81
RDS NOISE
82
TUN SMETER
83
RDS AFS L 2
84~86
NC
87
PWIC DC DET
88
LINE MUTE
89,90
NC
91
RDS DATA
92
RDS QUAL
93
NC
94
ACC DET
95
BU DET
96
AVSS
97
REF CON
98
VREF
99
AVCC
100
NC
6
I/O
Application
TUNER block (in µ-com) check
O
I/O
FM power supply control
-
-
Not used
-
I/O
MUTE
O
SVR discharge circuit (Not used)
O
Power IC stand-by control
O
Power IC MUTE
-
Not used
I
RDS decoder CLK input (RDS model only)
I
Destination setting 1
I
Destination setting 2
I
Destination change
I
Destination change
I
Destination change
I
FM noise detection
I
S meter input
TUN RDS MUTE output
O
(Not used in circuit, used in software)
-
Not used
I
DC offset detection
I
Line mute detection
-
Not used
I
RDS decoder DATA input
I
RDS decoder QUAL input
-
Not used
I
ACC power supply detection
I
Momentary power down detection
-
O
VREF control
-
-
-
Not used
Truth Value
Processing / Operation / Description
Table
Only when test mode, E2P OK: H, E2P NG: L, Normal: L
H: When FM is active, Hi-z: When FM is not active
Fix to output L
L: MUTE OFF, Hi-z: MUTE ON
When momentary power down by POWER OFF,
5 seconds : H, Thereafter: L
POWER ON: H, POWER OFF: L
While STANDBY source,
Momentary power down: L , While TEL MUTE: L
Fix to output L
e
Refer to the truth value table
e
Refer to the truth value table
r
Refer to the truth value table
r
Refer to the truth value table
r
Refer to the truth value table
H: Normal
L: FM/AM SEEK, AF search (L: When Tuner SRC Auto Zero)
* Same process with RDS AFS L
Fix to output L
TEL MUTE: 1V or lower, NAVI MUTE: 2.5V or higher
NAVI MUTE: 1V or lower and 2.5V or higher (J-TYPE)
Fix to output L
Fix to output L
L: ACC ON, H: ACC OFF
L: BU found, H: BU not found, momentary power down
Activated within 4ms after detection of momentary power down
Connect to VSS
Connect to VREF
Connect to REF CON
Connect to VCC
Fix to output L

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ckdc-mp676vCkdc-mp676f

Table of Contents