MODEL
RA-08MF / RA-08MEF
RA-10MF / RA-10MEF
RA-13MF / RA-13MEF
WINDOW TYPE ROOM AIR CONDITIONER
OPERATION AND INSTALLATION MANUAL

SAFETY PRECAUTION

Read the safety precautions carefully before operating the unit.
The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
!
WARNING ........ Incorrect methods of installation may cause death or serious injury.
!
CAUTION ......... Improper installation may result in serious consequence.
The sign in the fi gure indicates prohibition.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit
as described in the user's manual.
PRECAUTIONS DURING INSTALLATION
!
Please ask sales agent or qualifi ed technician for the installation of the unit. Water leakage, short
circuit or fi re may occur if install the unit improperly.
WARNING
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone.
Improper installation of earth line may cause electric shock.
!
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit
CAUTION
breaker, the danger of electric shock exists.
Do not install near location where there is fl ammable gas. The unit may catch fi re if fl ammable gas
leaks around it.
If drain pan is used, please ensure that when installing the drain hose, water is able to fl ow freely
without any obstruction.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
If abnormal situation arises (like burning smell), please stop the unit and turn off the circuit breaker.
Fault, short circuit or fi re may occur if the unit is continue to operate under abnormal situation.
!
Please contact your agent for maintenance. Improper maintenance may cause electric shock and
fi re.
WARNING
Please contact your agent if need to remove and reinstall the unit. Electric shock or fi re
may occur if you remove and reinstall the unit improperly.
PARTS IDENTIFICATION AND OPERATIONS
Model
Width
RA-08MF/RA-08MEF
18
1
", 470mm
13
1
2
RA-10MF/RA-10MEF
RA-13MF/RA-13MEF
22
3
", 560mm
14
3
64
AUTO SWING
When the AUTO SWING switch is turned to "ON" position, the vertical defl ectors automatically oscillate right and left
sweeping the cold air alternately to obtain comfortable cooling.
The vertical defl ectors will stop to swing when the AUTO SWING switch is turned "OFF"
OPERATION MODE SELECTOR DIAL
Stop the fan and cooling operation.
OFF
LO FAN
Fan operation only at low speed.
Fan operation only at high speed.
HI FAN
LO COOL
Cooling operation with low fan speed. This is recommended for sleeping comfort.
HI COOL
Cooling operation with high fan speed for maximum cooling power.
The start of operation will occur an abnormal sound (turbo sound) which doesn't affect the operation.
<
>
IA0000: A
Cabinet
1
Suction Grille
2
Front Cover
3
Horizontal Defl ectors
4
Vertical Defl ector
5
Air Exhaust Lever
6
Switch Panel Cover
7
Auto Swing Switch
8
Height
Depth
Operation Mode Selection Dial
9
Thermostat Dial
10
", 345mm
25
3
", 640mm
2
16
", 375mm
27
29
", 709mm
4
32
THERMOSTAT DIAL
Setting the desired room temperature. Turn the dial further clockwise for cooler indoor temperature.
!
CAUTIONS
Do not set the dial to "TEST" for normal usage. This setting is only for technician. If the unit
is operate at "TEST" for normal use, it may cause the evaporator frosted and consequence
of no cooling, noisy and water leakage may be found.
If the evaporator is found frosted, it means the temperature at evaporator is too low. Please
turn the dial anti-clockwise and check if any obstacle in front of air outlet and inlet like curtain.
When the compressor stops, please wait 3 minutes before turning the dial clockwise.
AIR DEFLECTORS
VERTICAL DEFLECTORS
Vertical defl ectors at both sides of outlets can be set to
either auto-swing or static position to direct discharge air
rightward, leftward or forward direction.
!
CAUTIONS
To avoid dew forming on the defl ectors which eventually may drip to the fl oor, please do not adjust horizontal defl ectors
extremely downward position or vertical defl ectors extremely leftward or rightward position during cool operation for a long
time.
Also, do not adjust the vertical defl ectors position by hand or any other object.
AIR EXHAUST LEVER
Set the air exhaust lever to the down ( OPEN) position for air
ventilation in the room. The air exhaust lever should normally be kept
in up ( CLOSE) position during cooling operation and in the case of
typhoon.
WASABI AIR PURIFYING FILTER
Always stop the operation before installing the wasabi air purifying fi lter.
1. Pull and remove the suction grille
Wasabi air purifying fi lter are not washable. It is recommended to use vacuum to clean it. It can be used use for 1 year
time. Type number for this wasabi air purifying fi lter is <SPX-CFH9W>. Please use this number for ordering when you
want to renew it.
NOTES ON OPERATION
TEMPERATURE AND HUMIDITY
Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F). Recommended
operation humidity should be below 80%. Continuous operation at over 80% humidity (indoor) will cause some dews form
on the outlet grille and defl ectors of the unit.
NOISE
In a quiet environment during the starting or stopping the operation, phenomena like fl owing sound of refrigerant in the
refrigerating cycle and rubbing noise from the fan casing may occasionally occur, but this is normal for the operation.
Water will be condensed on the evaporator coil and collected in the bottom tray, it is picked up by the condenser fan and
blown onto the condenser coil, this creates a "splashing" sound which is normal.
ODOR
The odor will possibly be emitted from the room air conditioner especially at the starting of operation and in a high
humidity condition. This is not abnormal phenomena because of the various kind of odors emitted by smoke, food stuffs,
cosmetics and others which may stick to the room air conditioner. So, the pre-fi lter and the evaporator regularly must be
cleaned to reduce the odor.
THE IDEAL WAYS OF OPERATION
Install curtain or blinds
Suitable Room Temperature
Warning
!
Freezing temperature
is bad for health and a
waste of electric power.
Do Not Forget To Clean The Pre-Filter
Dusty pre-fi lter will reduce the air
volume and the cooling effi ciency.
To prevent from wasting electric
energy, please clean the pre-fi lter
every 20 days.
FOR USER'S INFORMATION
The Air Conditioner And The Heat Source In The Room
Caution
!
If the amount of heat in the room is above the cooling capability of the air conditioner (for
example: more people entering the room, using heating equipments and etc.), the preset
room temperature cannot be achieved.
When Lightning Occurs
Warning
!
To protect the unit during lightning, please stop operating the unit and remove the plug
from the socket.
HORIZONTAL DEFLECTORS
Horizontal defl ectors at both sides of the outlets can
be set to direct discharge air upward, downward or
forward direction.
2. Remove the pre-fi lter
3. Install the wasabi air purifying
fi lter in the frame
4. Install back the pre-fi lter and
close the suction grille
Ventilation
Caution
!
It is possible
Do not close the room for a long period of
to reduce heat
time. Occasionally
entering the room
open the door and
through windows.
windows to allow the
entrance of fresh air.
Please Adjust Suitable Temperature
For Baby And Children
Please pay attention to the
room temperature and air fl ow
direction when operating the
unit for baby, children and old
people who have diffi culty in
movement.

Advertisement

loading

Summary of Contents for Hitachi RA-08MF

  • Page 1: Safety Precaution

    THERMOSTAT DIAL MODEL Setting the desired room temperature. Turn the dial further clockwise for cooler indoor temperature. RA-08MF / RA-08MEF RA-10MF / RA-10MEF CAUTIONS RA-13MF / RA-13MEF ● Do not set the dial to “TEST” for normal usage. This setting is only for technician. If the unit WINDOW TYPE ROOM AIR CONDITIONER is operate at “TEST”...
  • Page 2: Installation Instructions

    Connect the air conditioner with power source securely. ● Use a fuse as below: PRE-FILTER Voltage rating 50Hz 220V RA-08MF/RA-08MEF CAUTION If the pre-fi lter is clogged with dust, the air fl ow volume will be decreased and resulting in poor cooling performance, and RA-10MF/RA-10MEF Circuit Operatable 50Hz 198-242V increased operating noise.
  • Page 3 RA-08MF/RA-08MEF RA-10MF/RA-10MEF RA-13MF/RA-13MEF RA-08MF/RA-08MEF RA-10MF/RA-10MEF RA-13MF/RA-13MEF < > IA0000: A...
  • Page 4 RA-08MF/RA-08MEF RA-10MF/RA-10MEF RA-13MF/RA-13MEF (RA-13MF/RA-13MEF) 20mm 20mm RA-08MF/RA-08MEF RA-10MF/RA-10MEF RA-13MF/RA-13MEF < > IA0000: A...

This manual is also suitable for:

Ra-10mfRa-08mefRa-10mefRa-13mfRa-13mef