4.
LCD CMO 2K7
4.2
Models V315B1-L05 and V320B1-L05
4.2.1
Control Board
Disassembly
1. Place the panel on the foam bars, and remove the screws
of the metal cover (the number of screws depends on the
model).
Figure 4-3 Cover screws
2. Remove the cover in the direction as shown. Be sure not to
damage the FFCs.
Figure 4-4 Remove cover
3. Release the four FFCs from their connectors, use tweezers
if possible.
Figure 4-5 Release FFCs
4. You can now remove the Control Board.
Mechanical Instructions
H_16920_016.eps
110407
H_16920_017.eps
110407
H_16920_018.eps
110407
Reassembly
1. Place the panel on the foam bars, and place the Control
Board on the panel via the alignment pins.
Figure 4-6 Alignment pins
2. Insert and lock the FFCs into their connectors.
Figure 4-7 FFC insertion
3. Place the metal cover in the direction shown.
Figure 4-8 Cover placement
4. Secure the cover screws (refer to earlier figure "Cover
screws").
H_16920_020.eps
110407
H_16920_021.eps
110407