4 On-roof fitting and installation
1
Install the plugs (1) at the bottom of the collector.
Install the plugs (2) at the top of the collector.
Secure the plugs with the clamps.
Connect the collector flow and return to the system with
the connection tubes.
Lay the connection pipe at a gradient.
Note
Observe the installation instructions for the
auroFLOW plus system.
Check the connections for tightness.
Select the opening in the collector field that is nearest to
the flow connection.
On the selected collector, use a screwdriver (1) to push
the rubber stopper for the temperature sensor through to
the marking.
Do not remove the rubber stopper.
Push the temperature sensor through the rubber stopper
until you can feel significant resistance (2).
16
2
1
2
Installation manual auroTHERM classic 0020159946_01