Loop recording

This function records video in a continuous loop. A loop
recording area must be assigned to input/output ports
beforehand using the web menu. When the recorded video
reaches the capacity of the assigned area, recording
continues from the start, overwriting the previous
recording.
Network
Equipped with FTP server functions, the unit allows you to
transfer video files in MXF format via a network.
The unit is equipped with two Gigabit Ethernet ports as
standard. In addition, 10-Gigabit Ethernet option is also
supported by installing a board in the PCIe expansion slot.

Remote control

You can simultaneously connect up to four controllers that
support the RS422A (9-pin serial) signal format.
The SONY VTR/Disk Protocol, VDCP, and Odetics
control protocols are supported.
Remote control using parallel interface (25-pin) and
gigabit Ethernet is also supported.

Specifications

General
Recording format
XAVC
Power requirements
100 V to 240 V AC
Power consumption
Maximum 480 W
Inrush current
(1) Maximum possible inrush current at initial switch-
on (Voltage changes caused by manual
switching):
75A peak, 5 A r.m.s. (240 V AC)
(2) Inrush current after a mains interruption of five
seconds (Voltage changes caused at zero-
crossing):
75 A peak, 5 A r.m.s. (240 V AC)
Operating temperature
5 °C to 40 °C (41 °F to 104 °F)
Storage temperature
–20 °C to +60 °C (–4 °F to +140 °F)
Humidity
25% to 90% (non-condensing)
Mass
20 kg (44 lb. 1.5 oz.) (excluding options)
Dimensions
427 × 174 × 541 mm
7
(16
/
× 6
8
7
3
/
× 21
/
in.) (W×H×D)