Heat & Glo 6TRSI-AUD Owner's Manual page 35

Hide thumbs Also See for 6TRSI-AUD:
Table of Contents

Advertisement

Rear Vent - Vertical Termination
One Elbow
V
1
Figure 7.15
Two Elbows
V
Figure 7.16
H
1
1
H
2
Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. T • 11/15
3 ft.
2 ft.
4 ft.
6 ft.
8 ft.
INSTALLED
H
HORIZONTALLY
1
V
Minimum
1
1 ft.
305 mm
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.22 m
5 ft.
1.52 m
V
+ H
= 32 ft. (9.75 m) Maximum
1
1
H
= 8 ft. (2.44 m) Maximum
1
V
Minimum
H
1
1
914 mm
Back to Back 90º Elbows
610 mm
6 ft.
1.22 m
9 ft.
1.83 m
12 ft.
2.44 m
15 ft.
V
+ H
= 32 ft. (9.75 m) Maximum
1
1
H
+ H
= 15 ft. (4.57 m) Maximum
1
2
H
Maximum
1
2 ft.
610 mm
2 ft.
610 mm
4 ft.
1.22 m
6 ft.
1.83 m
8 ft.
2.44 m
+ H
Maximum
2
1.83 m
2.74 m
3.66 m
4.57 m
35