CLEANING

WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a
qualified service person. Heater
may need more frequent clean-
ing due to excessive lint from
carpeting, bedding material, pet
hair, etc.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
ODS/PILOT AND BURNER ORIFICE
Use a vacuum cleaner, pressurized air or
small, soft bristled brush to clean.
BURNER PILOT AIR INLET HOLE
The primary air inlet holes allow the proper
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep these holes
clear of dust, dirt and lint. Clean these air inlet
holes prior to each heating season. Blocked
air holes will create soot. We recommend that
you clean the unit every three months during
operation and have heater inspected yearly
by a qualified service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust,
dirt, lint and pet hair. To clean these parts we
recommend using compressed air no greater
than 30 PSI. Your local computer store,
hardware store or home center may carry
compressed air in a can. If using compressed
air in a can, please follow the directions on the
can. If you don't follow directions on the can,
you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
2. Inspect burner, pilot for dust and dirt.
3. Blow air through the ports/slots and holes
in the burner.
4. Never insert objects into the pilot tube.
110720-01M
Clean the pilot assembly also. A yellow tip on
the pilot flame indicates dust and dirt in the
pilot assembly. There is a small pilot air inlet
hole about 2" from where the pilot flame comes
out of the pilot assembly (see Figure 27). With
the unit off, lightly blow air through the air inlet
hole. You may blow through a drinking straw
if compressed air is not available.
Figure 27 - Pilot Inlet Air (Propane/LP
CABINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to re-
move dust.

TECHNICAL SERVICE

You may have further questions about instal-
lation, operation or troubleshooting. If so,
contact DESA Heating Products' Technical
Service Department at 1-866-672-6040.
When calling please have your model and
serial numbers of your heater ready.
You can also visit DESA Heating Products' tech-
nical service web site at www.desatech.com.
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• for propane/LP unit, propane/LP gas supply
may be low
You may feel your gas pressure is too low. If
so, contact your local gas supplier.

SERVICE PUBLICATIONS

You can purchase a service manual from
the address listed on the back page of this
manual. Send a check for $5.00 payable to
DESA Heating Products.
www.desatech.com