Floor Standing Type - Mitsubishi Electric PLA-RP-AA Technical Data Book

Heat pump air conditioners
Hide thumbs Also See for PLA-RP-AA:
Table of Contents

Advertisement

2-5. FLOOR STANDING TYPE

2-5-1.HEAT PUMP (without HEATER) AND COOLING ONLY TYPE
Model name
Indoor unit
Outdoor unit
Cooling
Capacity
Total input
EER
Energy label class
SHF
Heating *
Capacity
Total input
COP
Energy label class
Booster heater
Power supply
Phase
Cycle
Voltage
Breaker size
Indoor unit
Air flow
(Low-High)
External pressure
Sound level
(Low-High)
External finish
Dimension
Weight
Unit drain pipeO.D.
Outdoor unit
Air flow
Sound level at cooling
Sound level at heating *
External finish
Dimension
Weight
Refrigerant pipe
Gas side O.D.
size
Liquid side O.D.
Refrigerant pipe
Height difference
length
Length
* HEAT PUMP TYPE
NOTE:
1. Rating conditions (ISO T1)
Cooling
Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F)
Heating
Indoor : D.B. 20: (68˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Upper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C
Cooling
Lower limit D.B. 19˚C, W.B. 15˚C
Upper limit D.B. 28˚C
Heating
Lower limit D.B. 17˚C
H/P
PUH-P71VGAA
C/O
PU-P71VGAA
Btu/h
kW
kW
Btu/h
kW
kW
kW
[
1
Hz
50
V
230
A
32
CMM
CFM
Pa
dB(A)
W : mm
D : mm
H : mm
W : inch
D : inch
H : inch
kg
lbs
mm
inch
CMM
CFM
dB(A)
dB(A)
Ivory Munsell 5Y 7/1
W : mm
D : mm
H : mm
W : inch
D : inch
H : inch
kg
lbs
mm
inch
mm
inch
m
m
Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F)
Outdoor : D.B. 7: (45˚F)
Indoor
Outdoor
D.B. -5˚C
D.B. 24˚C, W.B. 18˚C
D.B. -11˚C, W.B. -12˚C
PSA-RP71GA
PUH-P71YGAA
PUH-P100VGAA PUH-P100YGAA
PU-P71YGAA
25,900
7.6
3.39
2.24
F
0.72
31,600
9.25
3.47
2.67
E
-
3
50
400
16
15-18
530-635
0
40-45
White Munsell 0.70Y 8.59/0.97
600
270
1900
23-5/8
10-5/8
74-13/16
43
98
20
13/16
50
1,770
49
51
900
330+20
855
35-7/16
13 + 3/4
33-5/8
79
174
15.88
5/8
9.52
3/8
Max. 50
Max. 50
W.B. 6: (43˚F)
3. Guaranteed voltage
198~264V, 50Hz : Single phase
342~457V, 50Hz : 3phase
4. Above data based on indicated voltage
Indoor unit
Single phase 230V 50Hz
Outdoor unit
Single phase 230V 50Hz / 3phase 400V 50Hz
32
PSA-RP100GA
PU-P100VGAA
PU-P100YGAA
32,800
9.6
3.75
2.56
E
0.72
36,700
10.75
3.86
2.78
E
-
1
3
50
50
230
400
32
16
24-31
850-1060
44-49
350
13-3/4
51
112
85
3,000
51
53
Ivory Munsell 5Y 7/1
900
330+20
1260
35-7/16
13 + 3/4
49-5/8
97
214
19.05
3/4
9.52
3/8
Max. 50
Max. 50