CAUTION - Investigational device. Limited by Federal law to investigational use. Getting you up to speed Quick Reference Guide...
Page 2
Animas Vibe System. ® ™ • Make sure to review all Contraindications, Warnings, Cautions, Precautions and other Safety information regarding your Animas Vibe ® ™ System. • You must take a fingerstick test (blood glucose (BG) test using a blood sample from your fingertip) with your BG meter and use that BG value to make any insulin or treatment decisions.
CAUTION - Investigational device. Limited by Federal law to investigational use. Home Screen Overview 2 : 27 Time of Day Approximate Battery Life Remaining Indicator Basal Rate Current Basal Rate 0.025U/Hr Insulin Remaining Insulin: 105U in Cartridge Status Menu Status Screens Shortcut Main Menu Shortcut Once the pump is set up, the Home screen is the first screen displayed when you “wake up”...
CAUTION - Investigational device. Limited by Federal law to investigational use. Main Menu Options MAIN MENU Screen: MAIN MENU Displays all MAIn MEnU options. Bolus • Bolus - Takes you to the normal Bolus screen. Suspnd/Resum If you have activated Advanced Bolus features, History the Bolus Menu will be displayed.
CAUTION - Investigational device. Limited by Federal law to investigational use. Pump Setup SETUP Screen: SETUP Lets you change your pump settings. Time/Date • Time/Date - Set the current time and date. Sound • Sound Settings - Adjust sounds for pump-related functions.
CAUTION - Investigational device. Limited by Federal law to investigational use. Bolus Menu BOlUS MENU Screen: BOLUS MENU Lets you calculate and deliver an insulin bolus. Normal ezCarb • Normal Bolus - Program an insulin dose for ezBG immediate delivery. Combo Bolus Reminders Advanced Bolus Features...
CAUTION - Investigational device. Limited by Federal law to investigational use. Basal Menu BASAl MENU Screen: BASAL MENU Lets you set up to 4 basal programs, and program Total 25.50U a Temp Basal. An “A” indicates the active basal program, and total basal insulin programmed for Temp A1-WEEKDAY the 24-hour period will appear on the top.
Page 9
CAUTION - Investigational device. Limited by Federal law to investigational use. History HISTORY Screen: HISTORY Lets you view important historical data records in your Bolus pump. Total Daily Dose (TDD) Tips: Alarm Prime • In order to navigate through records, scroll up to and Suspend highlight the record field and press to activate...
Page 10
CAUTION - Investigational device. Limited by Federal law to investigational use. Prime/Rewind ezPrime Screen: ezPrime Lets you properly align the cartridge and piston rod. Also lets you prime your infusion set tubing and fill Rewind your cannula or needle, before connecting to your Load Cart pump.
Page 11
CAUTION - Investigational device. Limited by Federal law to investigational use. Status STATUS Screens: STATUS 1 Lets you access basal and bolus delivery data, and ACTIVE BASAL other information about your pump. A1-WEEKDAY 24-Hr Total 13.60U 0.675U/Hr Insulin: 105U Home There are seven STATUS screens: •...
Page 12
CAUTION - Investigational device. Limited by Federal law to investigational use. Dexcom G4 CGM Sensor and Transmitter Overview Dexcom G4 Sensor and Applicator Dexcom G4 Transmitter Safety Lock Plunger Applicator Barrel Collar (contains small Introducer needle and Sensor) Transmitter Latch Release Tab Sensor Pod CGM Startup Steps...
Page 13
CGM warnings. Tip: For the pump to begin receiving CGM data, the pump must first be set up to communicate with the Transmitter. Refer to the Animas Vibe Owner’s Booklet for ®...
Page 14
CAUTION - Investigational device. Limited by Federal law to investigational use. CGM Setup CGM Setup Screen: CGM Setup Displays all CGM Setup options. Sounds High Alert Low Alert Sounds - Adjust sounds (beeps/vib) for CGM- Rise Rate related alerts. Fall Rate Out of Range High and low Alert - Set the levels for the alert that Transmitter...
Page 15
CAUTION - Investigational device. Limited by Federal law to investigational use. CGM Initial Session Startup • To enter the Transmitter ID, scroll to “Setup” on Transmitter the CGM Menu screen and press . Then select “Transmitter” from the CGM Setup screen and press to display the Transmitter screen.
Page 16
CAUTION - Investigational device. Limited by Federal law to investigational use. BG Calibration BG Calibration Screen: BG Calibrate Lets you enter fingerstick BG values for CGM calibration. When to calibrate mmol/L • When the 2-hour CGM startup period ends. – The pump will prompt you to enter BG values CALIBRATE from two separate fingersticks.
Page 17
An explanation of the Trend Arrows and the colour coding appears on the next page. † A symbol may appear in place of your current CGM reading on CGM Data and Trend screens. Refer to the Animas Vibe Owner’s Booklet for more information. ® ™...
Page 18
CAUTION - Investigational device. Limited by Federal law to investigational use. CGM Data Screen and Trend Screens Explanation of Trend Indicator symbols Rapidly rising: Your CGM glucose readings are rising more than 0.17 mmol/l each minute. Rising: Your CGM glucose readings are rising 0.11–0.17 mmol/l each minute. ...
CAUTION - Investigational device. Limited by Federal law to investigational use. CGM History CGM History Screen: CGM History Lets you review historical CGM records in your pump. Session Start Last BG Cal. • Session Start - Start time and date, elapsed time, Warnings and the amount of time remaining in the current session.
Page 20
CAUTION - Investigational device. Limited by Federal law to investigational use. Accessories Personalise your pump with skins, pump cases and covers, and re-order pump supplies, such as cartridges, infusion sets and batteries. Call the Australian Customer Care Team on 02 9882 3666 or order online today at www.amsl.com.au.
Page 21
U.S. patents including 6,656,148 and other patents pending. Dexcom and Dexcom G4 are either registered trademarks or trademarks of Dexcom, Inc. in the United States and/or other countries. Animas ® and Vibe™ are trademarks of Animas Corporation. All other trademarks and copyrights are property of their respective owners.