Samsung RF267AARS Service Manual page 65

Model code : rf267aars/xaa; rf26dbrs1/sml; rf267aabp/xaa; rf26dbbp1/sml; rf267aawp/xaa; rf26dbsh1/sml; rf267aash/xaa; rf26dbrs1/xsa
Table of Contents

Advertisement

TROUBLESHOOTING
4) If Ambient Sensor has trouble
ERROR Code
2¢ (-19¡ ) is recommended
DATA1.
Temperature table
** Measuring point of resistance value according to
Sensor **
Ambient : CN32#1
#4 measuring resistance value
** Placed in the right top table of upper hinge.
** 0 : Short trouble /
: Open trouble
Refer to circuit diagram in the manual
Sensor MICOM/Connector number
Ambient Connector CN32#1(White) to
CN1#3(Black) PCB typical Ground
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #59,
CN32#1(White) and CN1#3(Black) from
PCB typical Ground part are similar.
Checking method of Ambient Sensor resistance
CN32#1(White)
#4(White)
- Compare the temperature table after the
measure
38¢ (3¡ ) is recommended
Connector CN32 inserted
MAIN PCB Connector CN32#1(White)
to CN1#3(Black) normal?
IC01 MICOM #59 normal?
No trouble with PCB and temperature sensor
Recheck the bad contact of the connection
Checking method of Ambient Sensor voltage
- Measure the voltage of Sensor Check Point #7(IC01 MICOM #59)
on PCB or CN32#1(White)
- Compare the temperature table after the measure
Measuring voltage of CN32#1(White)
63
Start
Start
Is MAIN PCB
NO
correctly?
YES
YES
NO
Is Ambient Sensor
unit normal?
YES
YES
Is the voltage between
NO(0.6V > Measurement < 4.6V)
YES
YES
NO
Is the input voltage of
YES
CN1#3(Black)
CN1#3(Black) are below
Bad contact of connector/ insert correctly
Replace the temperature sensor
Recheck the wiring connection
Check the iced-solder, solder
bridging, disturbed solder
typical PCB Ground
CN1#3(Black)