If The Trouble Is Detected By Self-Diagnosis - Samsung RF267AARS Service Manual

Model code : rf267aars/xaa; rf26dbrs1/sml; rf267aabp/xaa; rf26dbbp1/sml; rf267aawp/xaa; rf26dbsh1/sml; rf267aash/xaa; rf26dbrs1/xsa
Table of Contents

Advertisement

TROUBLESHOOTING

4-2-1. If the trouble is detected by self-diagnosis

- The error of sensor will be displayed on the front of display.
when the error of sensor is detected at initial power ON, the appliance will not operated and display
of abnormal sensor part will blink.
- The appliance will not stop operating when the error of sensor is detected during operation of the
appliance.
But normal freezing might be not operated if the appliance is operated by the emergency operation
mode. You would better to check the appliance according to the self-diagnosis of the manual.
1) If ICE Maker Sensor has trouble
ERROR Code
2¢ (-19¡ ) is recommended
DATA1.
Temperature table
** Measuring point of resistance value according to
Sensor **
ICE MAKER : CN90#8 #4 measuring resistance value
** 0 : Short trouble /
: Open trouble
Refer to circuit diagram in the manual
Sensor MICOM/Connector number
ICE
Connector CN90#"4"(White) and
Maker
CN1#"3"(Black) PCB common Ground
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC02 MICOM #30,
CN90#4(White) and CN1#3(Black) from
PCB typical Ground part are similar.
Checking method of ICE Maker Sensor resistance CN90#
"8(Sky-blue)
#4"(White)
- Compare the temperature table after the measure.
38¢ (3¡ ) is recommended
Is MAIN PCB Connector
CN90 inserted correctly?
MAIN PCB Connector CN90#"4"(White) and
Is input voltage of IC02
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connection.
Checking method of ICE Maker Sensor resistance
- Measure the voltage of Sensor Check Point #6(IC02 MICOM #30)
on PCB or CN90#4(White) CN1#3(Black)
- Compare the temperature table after the measure.
Measuring voltage of CN90#4(White)
60
Start
NO
YES
NO
Is ICE Maker Sensor
unit normal?
YES
Is the voltage between
NO(0.6V > Measurement < 4.6V)
CN1#"3"(Black) normal?
YES
NO
MICOM #30 normal?
YES
CN1#3(Black) are below.
Bad contact of connector/ insert correctly
Replace the temperature sensor
Recheck the wire connection part
Check the iced-solder, solder
bridging, disturbed solder.
typical PCB Ground
CN1#3(Black)

Hide quick links: