Inspect the sealants around windows and doors at least
every three months. Also inspect roof vents, other roof
components, moldings at front and rear caps, and perimeter
molding. It any of the following defects are evident during
inspection, the affected areas must be resealed.
»
Excessive amount of sealant protruding from joints.
»
Sealant cracked or peeling.
»
Voids in sealant.
If you find any of the above defects:
1. Use a plastic scraper io remove any excess sealant, any
cracked or peeled sealant, or any voids in the sealant.
2. Clean all areas to be resealed with mineral spirits and
clean rags.
3. Make sure that all areas to be resealed are absolutely dry
before new sealant is applied.
PACE ARROW
MAiNTENANCE
DOOR, WINDOW,
ROOF COMPONENT
AND MOLDING
RESEALING
./1
NOTE
Do not seal the bottom
flanges of windows and
doors. Special gaps in
the sealant have been
intentionally left in the
bottom flange to provide
exterior drainage in the
event of leakage.
WARNING
Mineral spirits is a flam-
mable
liquid.
Use
extreme care when han-
dling and using. Do not
expose to open flame,
sparks, or smoking mate-
rial. Do not use in unven-
tilated areas.
~
1-
-~