Connecting Two Z•025s in One Zone to the MCU
Connecting more than one Z•025 per zone requires the
use of the ELAN Z•027 12 VDC Regulated Power Supply.
In the diagram bewlow, two Z•PADs with two Z•025 mod-
HDC2010
SENSE A
SENSE B
SENSE A
SENSE B
VAR
FIXED
VAR
FIXED
© ELAN Home Systems • 2003 • All rights reserved. 2/03
ONNECTIONS
Z027
12VDC
Regulated
Power Supply
(C45P)
NOTE:
Program Relays to
P+D+TM if using
Wholehouse Page only, or
to VCO1, VCO2, etc. if
using Zone-Specific Page
(see HD Installation
Manual Pages 4.17 and
5.11).
:
ules are connected back to the same zone on an
HDC2010 Dual Zone Output Card.
025
INSTALLATION MANUAL
(C45P)
(C45P)
Never connect the 12VDC
DO NOT OVERTIGHTEN
from the HDC2010 Zone
MOUNTING
Card to the keypads when
SCREWS––HAND TIGHT-
using an external power
EN ONLY.
supply.